MN761
Parameter Descriptions 7-17
7.3 Function Group2
Continued
Parameter #
Access
Parameter Name, Value Range, Description and Preset Value
RW
Monitoring Item
(Range:
0- Output Voltage [V]
1- Output Power [kW]
2- Torque [kgf-m])
Selects the item to be monitored/displayed in vOL parameter.
Preset Value:
0
RW
Gain for Motor RPM
(Range: 1-1000%)
Sets the display units motor speed (r/min) to mechanical speed (m/min).
Preset Value:
100
RW
Software Version
(Range: 0-10.0)
Displays the inverter software version.
Preset Value:
X.X
RW
Second Motor Accel Time
(Range: 0-6000sec)
Sets the acceleration time for the second motor.
Preset Value:
5.0
Parameter is only displayed when a Digital Input
(I20-I24)=12.
RW
Second Motor Decel Time
(Range: 0-6000sec)
Sets the deceleration time for the second motor.
Preset Value:
10.0
Parameter is only displayed when a Digital Input
(I20-I24)=12.
RW
Second Motor Base Speed
(Range: 30-400Hz)
Sets the rated frequency of the second motor. See motor nameplate.
Preset Value:
60.00
Parameter is only displayed when a Digital Input
(I20-I24)=12
RW
Second Motor Volts/Hz Pattern
(Range:
0- Linear
1- Square
2- User Defined Volts/Hz Pattern)
Sets the Volts/Hz pattern for the second motor. (See F30 description).
Preset Value:
0
Parameter is only displayed when a Digital Input
(I20-I24)=12
RW
Second Motor Forward Torque Boost
(Range: 0-15%)
Sets the of torque boost level for the second motor during forward run.
Set as a percentage of maximum Output Voltage.
Preset Value:
5
Parameter is only displayed when a Digital Input
(I20-I24)=12
RW
Second Motor Reverse Torque Boost
(Range: 0-15%)
Sets the of torque boost level for the second motor during reverse run.
Set as a percentage of maximum Output Voltage.
Preset Value:
5
Parameter is only displayed when a Digital Input
(I20-I24)=12
Summary of Contents for VS1SM
Page 1: ...Installation Operating Manual VS1SM Single Phase AC Drive 10 07 MN761...
Page 10: ...2 2 General Information and Ratings MN761...
Page 28: ...6 8 Using the Keypad MN761...
Page 57: ...MN761 Customizing for Your Application 8 1 Chapter 8 Customizing for Your Application...
Page 58: ...8 2 Customizing for Your Application MN761...
Page 63: ...MN761 Parameter Tables B 1 Appendix B Parameter Tables Refer to Chapter 7...
Page 64: ...B 2 Parameter Tables MN761 B 1 1 Basic Parameters Continued...
Page 69: ...Baldor District Offices...