MN761
Parameter Descriptions 7-5
7.2 Function Group1
Continued
Parameter #
Access
Parameter Name, Value Range, Description and Preset Value
RW
Start Speed
(Range: 0.1-10Hz)
Sets initial speed of the inverter.
Preset Value:
0.50
RW
Speed High/Low Limit Selection
(Range: 0=No, 1=Yes)
Sets whether the high/low limits (F25 and F26) are used.
Preset Value:
0
RW
Speed High Limit
(Range: 0-400Hz)
Sets the upper speed limit. Cannot be greater than F21.
Preset Value:
60.00
Parameter is only displayed when F24 =1.
RW
Speed Low Limit
(Range: 0.1-400Hz)
Sets the lower speed limit. Cannot be greater than F25 or less than F23.
Preset Value:
0.50
Parameter is only displayed when F24 =1.
RW
Torque Boost
(Range:
0- Manual. Torque levels set in F28 and F29 are used.
1- Auto. Automatically boosts the output voltage by calculated torque boost
value using motor parameters.
Sets how Torque Boost is applied.
Preset Value:
0
RW
Forward Torque Boost
(Range: 0-15%)
Sets the torque boost level during forward run.
Excess boost may cause motor overheating.
Preset Value:
5
FWD
Time
REV
Vol tage
No torque boost
100%
FWD Tq Boost
REV Tq Boost
RW
Reverse Torque Boost
(Range: 0-15%)
Sets the torque boost level during reverse run.
Excess boost may cause motor overheating.
Preset Value:
5
Summary of Contents for VS1SM
Page 1: ...Installation Operating Manual VS1SM Single Phase AC Drive 10 07 MN761...
Page 10: ...2 2 General Information and Ratings MN761...
Page 28: ...6 8 Using the Keypad MN761...
Page 57: ...MN761 Customizing for Your Application 8 1 Chapter 8 Customizing for Your Application...
Page 58: ...8 2 Customizing for Your Application MN761...
Page 63: ...MN761 Parameter Tables B 1 Appendix B Parameter Tables Refer to Chapter 7...
Page 64: ...B 2 Parameter Tables MN761 B 1 1 Basic Parameters Continued...
Page 69: ...Baldor District Offices...