MN761
Using the Keypad 6-7
Reset all parameters to factory settings
: Restoring factory settings (H93) will overwrite all
parameter values.
Action
Description
Display
Comments
Apply Power
Press the
"
key to go to
Function Group 2.
The jump code in
Function Group 2
Press Enter to edit the
jump code.
Change the code from 1
to 93.
Press the
Y
key 2 times
to increment to 3.
Press the
A
key to move
1 digits to the left
Press the
Y
key 9 times
to increment to 9.
Jump code is now 93.
Press Enter to view to
F93.
Press Enter to jump to
H93
Press Enter to edit to
change the setting
Press the
Y
key to
change value to 1 (reset
all parameter values).
Press Enter to restore all
factory settings.
Press Enter to rest
values. The display will
flash for a few seconds
until the values are reset
to factory settings.
Summary of Contents for VS1SM
Page 1: ...Installation Operating Manual VS1SM Single Phase AC Drive 10 07 MN761...
Page 10: ...2 2 General Information and Ratings MN761...
Page 28: ...6 8 Using the Keypad MN761...
Page 57: ...MN761 Customizing for Your Application 8 1 Chapter 8 Customizing for Your Application...
Page 58: ...8 2 Customizing for Your Application MN761...
Page 63: ...MN761 Parameter Tables B 1 Appendix B Parameter Tables Refer to Chapter 7...
Page 64: ...B 2 Parameter Tables MN761 B 1 1 Basic Parameters Continued...
Page 69: ...Baldor District Offices...