Chapter 4. Initial setup and programming
70
AquaTrans™ AT600 User’s manual
4.7.8 Programming the fluid type
If the fluid type is known, the meter performs flow rate calculations based on the programmed parameters for that
fluid. However, if the fluid type is not known, you must activate the tracking windows function described below.
Relocating the transducers is not necessary.
Note:
Fluid SOS, maximum SOS and minimum SOS are all programmed in the same manner.
Select the appropriate option and press [√] to
return to the previous screen.
Select fluid type and press [√]. The following screen opens.
If the fluid type is water, select water and press [√] to return to the
previous screen. If the fluid is not water, select other and press [√]. A
screen similar to the following opens.
To disable the tracking window, select no and press [√]. A screen
similar to the following opens, so that you can enter the speed of
sound (fluid SOS.) in your fluid. If you don't know your fluid SOS, you
should enable the tracking window so that the meter can detect it
automatically. If the tracking window is enabled, select Yes and
press [√]. A screen similar to the following opens. Enter the maximum
SOS and minimum SOS.
Press [√] again, and a screen similar to the
following opens.
Summary of Contents for Panametrics AquaTrans AT600
Page 1: ...panametrics com BH001C11 Rev F AquaTrans AT600 User s manual...
Page 2: ......
Page 4: ...ii no content intended for this page...
Page 10: ...Contents viii AquaTrans AT600 User s manual no content intended for this page...
Page 150: ...Chapter 6 Communication 140 AquaTrans AT600 User s manual no content intended for this page...
Page 158: ...Appendix B Specifications 148 AquaTrans AT600 User s Manual no content intended for this page...
Page 162: ...Appendix C Specifications 152 AquaTrans AT600 User s Manual no content intended for this page...
Page 172: ...Warranty 162 AquaTrans AT600 User s Manual...
Page 173: ......