53
53
Adjusting the 90° Bevel Stop
Note: The tilt scale reads "0" when the blade is 90° to the table.
90° Check and Adjustment
1. Disconnect and lockout power to the saw!
2. Raise the blade to its highest position and tilt it toward 0° until it stops and cannot be tilted
any more.
3. Place a 90° square against the table and blade so it contacts the blade evenly from bottom
to top. Verify that blade tooth does not obstruct the placement of the square.
If the blade is 90° to the table, then no adjustment is needed. When the blade stops at 90° to
the table, verify that the tilt indicator pointer points to the 0° mark on the scale.
If the blade is not 90° to the table, you will need to adjust the 90° stop screw.
Tilt the blade to about 5°, so there is room for
the stop bolt to move.
4. Open the motor access cover, loosen the jam
nut (A), adjust the stop bolt up or down as
needed to stop the blade at 90°. Repeat Step 3
- 5 until the blade stops at 90°.
5. Tighten the jam nut, and then close the motor
cover.
Tilt Indicator Pointer Adjustment
1. Remove the blade height lock knob.
2. Loosen the blade height handwheel set screw
and remove the handwheel.
3. Loosening the screw (B) just enough to allow
the pointer to move.
4. Move the pointer as needed, then tightening
the screw and install the handwheel.
B
A
Summary of Contents for TS-1248P
Page 4: ...52 Saw Body Parts List A B 94...
Page 81: ...77 77 ELECTRICAL DIAGRAM...
Page 82: ...78 78 ELECTRICAL CONNECTIONS...
Page 83: ...79 79 BLADE GUARD MITER AND ACCESSORIES PARTS DIAGRAM A A...
Page 86: ...82 82 FENCE PARTS DIAGRAM...
Page 89: ...85 85 52 EXTENSION TABLE AND RAILS PARTS DIAGRAM...
Page 91: ...87 87 SAW BODY PARTS DIAGRAM A...
Page 92: ...88 88 SAW BODY PARTS DIAGRAM B...
Page 103: ...99 99 NOTES...