64
64
Initial Calibration (Tune)
The initial tune needs to be performed after the batteries are changed or if the is not reading the
correct measurement. For example, if you move the fence 10” and the DRO displays a number
less than or greater than that distance. Verify the measurement with a separate tape measure or
ruler. If the measurement displayed on the DRO is incorrect, perform the initial tune and retest.
1. Disconnect and lockout power to the saw!
2.
Place the fence on the rail about 2” – 3” to the right of the blade. Leave the handle in the
unlock position.
3. Press the Menu/Return
button, then press the ABS/REL
button twice for “tune” to appear on screen.
4. Press the Zero/Return
button and slowly move the
fence (about 1” per second) to the right away from the blade. The
tape measure icon will begin to blink. Continue to move the fence
until tuning is complete (typically about 2
– 3 seconds).
5. When the tuning is complete, the screen will change to display
numbers.
6. The DRO is ready for operation.