Setting Up - IBM Mainframe (zSeries)
AXIS 5570e User’s Manual
39
Note:
Node Definitions
The example below shows how the print server PU and LU definitions
may be coded in a local major node definition:
* 5570e DSPU DEFINITION
DSPU5570e5570ePU CUADDR=E31,
X
MODETAB=MODE3290,
X
PUTYPE=2,ISTATUS=ACTIVE,MAXBFRU=1
DSPULU02 LU
LOCADDR=2
X
SSCPFM=USSSCS,
X
USSTAB=USSTAB,
X
PACING=1,
X
VPACING=2,
X
ISTATUS=ACTIVE,
X
LOGAPPL=MWTC,
X
DLOGMOD=SCS5570e
DSPULU03 LU
LOCADDR=3,
X
SSCPFM=USSSCS,
X
USSTAB=USSTAB,
X
PACING=1,
X
VPACING=2,
X
ISTATUS=ACTIVE,
X
LOGAPPL=MWTC,
X
DLOGMOD=SCS5570e
In the PU definition,
IDNUM
should be set to the five last digits of the Axis Network Print
Server node address,
NODE_ADDR
.
By default
NODE_ADDR
stands for the five last digits of
the Axis Network Print Server serial number.
In the path definition,
PATH DIALNO
should be comprised with its first two digits equal to
the place holder, the next two set to the SAP and the remaining twelve digits set to the Axis
Network Print Server Ethernet or Node address. By default the Ethernet/Node address is
identical to the Axis Network Print Server serial number. A valid
GRPNM
must also be
supplied.
In the LU definition, the
LOCADDR
number maps to the Logical Printer number of the Axis
Network Print Server. The first eight Local Addresses pass the printout through Logical Printer
1-8. However, some IBM systems do not allow Local Address 1 to be used for printing. Refer
to
“Logical Printers for Customized Printing”
on page 153 for more information about
logical printers.