![Axis 27980R1 User Manual Download Page 178](http://html1.mh-extra.com/html/axis/27980r1/27980r1_user-manual_3038772178.webp)
SNA Gateways
178
AXIS 5570e User’s Manual
3. Configure SNA Network ID. Either change the default value or let it stay on
default.
4. Configure Data Link Adapters. The configuration is done on the Data Link
Adapters Definitions screen by pressing insert for a new adapter config, then
you always enter the Logical adapter name, Link type, Logical adapter
number and Service status.
5. Configure PU and LUs. On the Configure PU Profile screen you can set
default LU attributes, starting dependent LU address, number of dependent
LUs, give CP a name, enable off-line test mode, status assignment of LUs
activated by host, status call host at workstation attach, status PU profile
start-up and logical adapter name. On the Configure Dependent LUs screen
you can set VTAM LU name, lock for a session, LU type and model and
preserve host session.
6. Assign LU Resources and Access Control Lists (ACLs). On the Configure
Dedicated LUs you can dedicate a LU to a person or device or group of
persons. This person(s) is described in the access control lists.
7. Configure Downstream PU. Choose Configure Downstream PUs and press
insert. Give it a name and fill in starting LU address or leave at default, type
in number of DownStream LUs and logical adapter name:
The CSCON adds new parameters according to the adapter type you have
set. The resulting screen can look like this:
Concentrator gateway,
Microsoft
This is an outline of the procedure for configuring to a Microsoft SNA
Server. More information is provided in the Support section of the Axis
Web site at http://www.axis.com
1. Configure host connection.
2. Configure downstream connection.
3. Select host connection and assign one or more DownStream LUs to it.
4. Select downstream connection and associate the DownStream LUs (from
step 3) with that connection.
5. If necessary, reorder the DownStream LU numbers, that is, the LU numbers
used by the downstream system.
6. To connect multiple PUs (boxes) repeat steps 2-5.
Configure Downstream PU Connection
Downstream PU name (CP name):
_____________________________DPUname
Starting downstream LU address: ___________________________2
Number of downstream LUs: _________________________________1
Logical adapter name: _____________________________________
Netware Comm Services Config V2.0 Wednesday 1999 September 4
16.27
Configure LUs for Downstream PUs _______________Downstream
PU: AXIS5570e
DLU __Address __PU Profile __LU Address __LU Type __Model
__VTAM LU Name
002 __(0x02) ____SAA_MAIN ____15 (0x0F) __Printer
__________________ACP4