![Axis 27980R1 User Manual Download Page 175](http://html1.mh-extra.com/html/axis/27980r1/27980r1_user-manual_3038772175.webp)
SNA Parameter Overview
AXIS 5570e User’s Manual
175
Changing
Parameters after
Auto-configuration
If you want to change some of the critical configuration parameters after
auto-configuration is completed, you should first set AUTODIAL to NO,
then remove all descriptions in the AS/400, and then change the
parameter(s) and set AUTODIAL to YES to initiate a new configuration
process.
Auto-configuration and Mapping
The configuration created in the AS/400 and the mapping to the Axis
Network Print Server as a result of the auto-configuration process is
illustrated by the figure below.
% password
(If you have not changed the default
password (pass), the password is optional.)
PRDRIVER = PCL5;
%+
NODE_SAP = 4;
H1_SAP = 4;
AUTODIAL = NO;
%CONFIG--
PREMUL = 3816;
SYSL = 37;
BIN1 = LETTER, COR;
SAVE;
%CONFIG-
APPC-controller
APPC-device
RWS-controller
Printer device #1
Printer device #2
Printer device #3
Logical Printer #1
Logical Printer #2
Logical Printer #3
Configuration in the
AXIS 5470e
Configuration in the
AS/400
Logical mappings
LU 6.2 conversation