![Axis 27980R1 User Manual Download Page 181](http://html1.mh-extra.com/html/axis/27980r1/27980r1_user-manual_3038772181.webp)
Extended IBM Printer Emulation
AXIS 5570e User’s Manual
181
•
width
is the bar code module width in 1/1000 inch. Valid range is 1 to
1000. The default value is 12.
•
height
is the bar code element height in 1/24 inch. Valid range is 1 to
500. The default value is 12.
•
text mode
selects if human readable text is printed under the bar code
or not. ‘YES’ or ‘ON’ will turn on text, ‘NO’ or ‘OFF’ will turn off text.
The default mode is ‘ON’.
•
check mode
selects if a check digit will be generated or not. ‘YES’ or
‘ON’ will generate a check digit, ‘NO’ or ‘OFF’ will not generate a check
digit. The default mode is ‘ON’. The check digit will always be generated
for bar code types UPCA, EAN8 and EAN13, regardless of the setting of
check mode
.
To set up the BAR parameter, use the
%CONFIG
command in your
document. To print bar codes, bar code commands may be included
anywhere in your documents. They begin with ‘percent-slash’ (
%/
)
followed by the word BAR. Then follows the number of the bar code
definition to be used, a comma, and the sequence to be printed. The
command is ended by a semi-colon (;).
Setting up the bar code parameters and printing bar codes
Once the BAR parameter has been set up, you will only need to use the bar
code commands to print the bar codes
Resulting printout:
AXIS Cobra products
compatibility
The Axis Network Print Server supports a subset of the extended printer
emulation syntax of the AXIS Cobra products, including the bar codes
syntax. For more information, please refer to the AXIS Network Print
Server Technical Reference supplied on the AXIS Network Product CD.
%
BAR 0 = EAN8,12,4,ON;
BAR 1 = EAN8,12,8,ON;
SAVE;
%CONFIG-
%/BAR 0,"0123456"; %/BAR 1,"0123456";
%/BAR 0,"0123456"; %/BAR 1,"0123456";
0123 4565
0123 4565