10 Program Instructions
96
© Copyright Reserved Autonics Co., Ltd.
10.2.4
OPT (output port ON pulse)
It turns the set output port ON during the set ON time.
Instruction
DATA
OPT
Instruction
On time
Output port
Next step
On Time: Set the ON time for output port.
Setting range is 1 to 10,000msec.
Output port: Set the output port number.
For more information about output port number,
refer to ‘8.2.2General Output (AiC-D: 10, AiC-D-B: 9)’.
Next step
ON: It moves to the next step regardless of output operation.
OFF: It turns the set output port ON during the set ON time. After the time, it moves
to the next step.
10.2.5
CMP (compare output)
It outputs trigger pulse for the set period.
Instruction DATA
CMP
Instruction Pos
Port
Mode
Width
Period
For more information, refer to ‘8.2.1.3Compare1, Compare2’.
Position
: Set the trigger position of output signal.
Setting range is 1 to 10,000 msec
Compare Port
: Set the compare output port number.
Compare Mode
: Set the compare output mode.
Pulse Width
: Set the output pulse width.
Applied when compare mode is 3.
Setting range is 1 to 10,000 msec.
Pulse Period
: Set the output pulse period.
Applied when compare mode is 3.
Setting range is 1 to 2,147,483,647.
Summary of Contents for AiC-D-20LA
Page 2: ......
Page 19: ...1 Product Overview Copyright Reserved Autonics Co Ltd 19...
Page 34: ...3 Dimensions 34 Copyright Reserved Autonics Co Ltd...
Page 40: ...5 Connection 40 Copyright Reserved Autonics Co Ltd 5 Connection 5 1 Standard Type...
Page 41: ...5 Connection Copyright Reserved Autonics Co Ltd 41 5 2 Built in Brake Type...
Page 45: ...6 Characteristics Copyright Reserved Autonics Co Ltd 45...