10 Program Instructions
ⓒ Copyright Reserved Autonics Co., Ltd.
95
10.2
Input/Output Instruction
10.2.1
ICJ (input condition jump)
It is for jumping to the set step (Step No.) when the selected input port is activated.
When the input port is deactivated, it runs the next step.
Instruction
DATA
ICJ
Instruction
Step no.
Input port
Step No.: Set the step number to jump. Setting range is 0 to 255.
Input port: Select Input port number.
For more information of input port number, refer to ‘8.1.2General Input (9)’.
At the loop between REP, RPE instruction, do not use ICJ (Input condition jump).
10.2.2
IRD (input wait)
It is for moving the next step when the selected input port is activated.
When the input port is deactivated, it waits at the current step until the active status.
Instruction
DATA
IRD
Instruction
Input port
Input port: Select the input port number.
For more information of input port number, refer to ‘8.1.2General Input (9)’.
10.2.3
OPC (output port ON/OFF)
Instruction
DATA
OPC
Instruction
Output port
Level
It turns ON/OFF the selected output port.
Output port: Select the output port number.
For more information of output port number,
refer to ‘8.2.2General Output (AiC-D: 10, AiC-D-B: 9)’.
Level: When setting as Enable, it turns ON. When setting as Disable, it turns OFF.
Summary of Contents for AiC-D-20LA
Page 2: ......
Page 19: ...1 Product Overview Copyright Reserved Autonics Co Ltd 19...
Page 34: ...3 Dimensions 34 Copyright Reserved Autonics Co Ltd...
Page 40: ...5 Connection 40 Copyright Reserved Autonics Co Ltd 5 Connection 5 1 Standard Type...
Page 41: ...5 Connection Copyright Reserved Autonics Co Ltd 41 5 2 Built in Brake Type...
Page 45: ...6 Characteristics Copyright Reserved Autonics Co Ltd 45...