AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling & Floor Type
50
7. Explode view
ALCF-H18/4DR1
No.
BOM Code
Chinese Name
Part Name
Quantity
1
16420012000002
滤网
Air-inlet filter
2
2
16420010000002
格栅
Air-inlet grill(white)
2
3
16420015000002
左装饰板
Left side adornment plank
1
4
16421038000207
电控盒
The electricity controls a box
1
5
16421038000208
电控盒盖
The electricity controls a box
of cover
1
6
11220544000008
压线座 双联
Compress tightly electric wire
seat
1
7
16427001000010
端子板
5
位
(600V 4mm2)AB
Terminal board
1
8
16422005000033 (ROHS)
变压器
TDB-14-B4B(PTC)
Transformer
1
9
11330010000054 (ROHS)
电容
2.5μF/450V A.C
Capacitor
1
10
11222009002538 R
控制板
QRD-SN3F(18-60)K(485)-SYE1(
SY)
PCB board
1
11
16430001000196
电机
YSK-40W-4
Motor
1
12
16420014000007
左盖板
The left side covers
1
13
16421001000029
左挂架
Left suspend plate
1
14
16321006000005
左侧板组件
Bracket board welding
assembly of left-hand
1
15
16428001000034
左泡沫
Left foam
1
16
16421018000004
背板组件
Chassis welding assembly
1
17
16324006000014
蒸发器总成
Evaporator assembly
1
Summary of Contents for AL-H18/4DR1(U)
Page 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Page 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Page 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Page 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Page 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Page 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Page 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Page 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Page 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Page 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Page 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Page 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Page 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Page 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Page 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Page 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Page 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Page 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Page 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Page 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Page 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Page 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Page 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...