AUKS DC Inverter 1 Drive1 50HZ R410A Controller
141
4. “COOL”button
* Press the
COOL
button, you can directly enter cooling mode.
5. “HEAT”button
* Press the
HEAT
button, you can directly enter cooling mode.
*
Note:
cooling only unit has no heating function.
6. “SWING”button (SWING ←→and SWING ↑↓ )
Press this button to start up/down (left/right) swing function, press it again, fix louver position.
* Up/down (left/right) setting is only valid in this mode; it will not affect louver position in other
modes.
* Up/down (left/right) swing has memory function, it can keep primary setting when turn off then
turn on or switch from other modes to primary mode.
7. “HEALTH” button
* Press this button; you can turn on or off the health function.
8. “SLEEP” button
* Press SLEEP button, the sleeping indicator light of indoor unit flashes on.
* The air-conditioner runs in sleeping mode for 10 hours and quiet sleep mode, recover back to
former mode.
* The unit will turn off automatically if the timing mode is running out of time.
* Note: press the MODE or ON/OFF button, the remote controller clears sleeping mode away.
9. “iFEEL” button
* Press this button to set “iFEEL”function. The LCD shows the actual room temperature when the
function set and it shows the setting temperature when the function cancelled.
* This function is invalid at Fan mode.
10.“DISPLAY” button
* In display mode, press button once, switch off “DISPLAY”, Press “DISPLAY” again, LCD will show
ambient & setting temperature after flashing 5s. It's convenient for users to check ambient or
setting temperature at any time in darkness.
11.“iCLEAN” button
* When remote controller is at the off state, press this button, the unit runs “iCLEAN” function .
* The purpose of this function is to clean dust on evaporator and dry the inside water of evaporator
and to prevent the evaporator going moldy due to water deposition and boasting strange smell.
* After setting “iCLEAN” function, press “iCLEAN” button or “ON/OFF” button to quit.
* The clean function will stop working after about 30 minutes running without any operation.
12. “ELE.H”button (for AUKSiliary electric heating IDU)
In heating mode, press this button,
AUKSiliary
electric heating will work.
13. “Anti-FUNGUS”button
* The purpose of this function is to dry the inside of the evaporator and to prevent the evaporator
from going mouldy due to water deposition and thus dispersing strange smell.
* To operate the function: under “off” status of the A/C and
the remote controller, press “
Anti-UNGUS
”button for
one time, the buzzer keep beeping five times again after five times beep, indicating that this
function is ready.
* To cancel the function: 1. under “OFF ” status of the A/C and the remote controller, press “
Anti-
FUNGUS
”button again.
14. “SPOT SWING”button
* Press this button, the horizontal wind direction vanes can swing automatically, when you have the
desired vertical wind direction.
Summary of Contents for AL-H18/4DR1(U)
Page 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Page 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Page 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Page 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Page 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Page 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Page 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Page 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Page 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Page 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Page 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Page 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Page 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Page 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Page 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Page 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Page 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Page 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Page 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Page 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Page 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Page 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Page 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...