AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit
103
Heat insulation package of piping
◇
Use heat insulation material with good insulation performanCF to wrap the pipe.
Notes
Drainage pipe and connection piping should be wrapped by heat insulation material respectively or there
will be dew or leakage
During the high temperature working environment, our air conditioner is proved my dew conditioner
experiment. But if it keeps on working during the high humidity (the dew temperature is more than23
℃
)
environment which may lead to water leakage, in such condition please use following additional
insulation material:
◇
Glass fiber insulation material with the thickness between 10~20mm can be used.
◇
The part of indoor unit which get in touch with the back side of ceiling should pasted with insulation
material.
◇
Besides the previously more than 8mm thick insulation material, connection piping (both gas pipe and
liquid pipe), drainage pipe should be wrapped by additional 10~30 mm thick insulation material.
To seal the hole on the wall.
◇
To prevent rainwater or other foreign bodies from entering the room and air-conditioner after installing
the tubing and drain pipe, the gap between wall hole and tubing, drain pipe and electric wire should be
sealed with mastic, sealant rubber or putty, or poor performance or leakage will result
◇
If the outdoor unit is higher than indoor unit, tubing should be bent to ensure that the lowest point of
the tubing is lower than the wall hole to prevent rainwater entering the room or air-conditioner along
the piping system.
Summary of Contents for AL-H18/4DR1(U)
Page 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Page 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Page 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Page 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Page 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Page 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Page 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Page 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Page 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Page 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Page 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Page 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Page 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Page 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Page 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Page 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Page 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Page 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Page 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Page 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Page 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Page 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Page 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...