AUKS DC Inverter 1 Drive1 50HZ R410A Four-way cassette
14
Drainage
mm
R3/4in(DN20)
R3/4in(DN20)
Max. Refrigerant Pipe Length
m
50
50
Max. Difference In Level
m
30
30
Operation Temperature Range
℃
16~32
16~32
Ambient Temperature Range(Cooling/Heating)
℃
16~49/-15~24
16~49/-15~24
Connection Wiring
Power Wiring( Indoor)
mm
2
3×1mm
3
3×1mm
3
Power Wiring( Outdoor)
mm
2
5×1.5mm
3
5×1.5mm
3
Signal Wiring
mm
2
2×1mm
2
2×1mm
2
Wireless Remote Controller
YKR-L/300E
YKR-L/300E
Application Area
m
2
56-93
64-107
Qty’per 20’& 40’&40HQ(Only For Reference)
Set
26/54/54
26/54/54
Note:
1.
Working condition of the cooling capacity measured: Inside the room DB temperature 27
℃
,WB
temperature19
℃
;Outside of the room DB temperature 35
℃
,WB temperature 24
℃
;Working condition
of the heating capacity measured:Inside the room DB temperature 20
℃
,Outside of the room DB
temperature 7
℃
,WB temperature 6
℃
.
2. Parameters above are all measured when the connecting pipe is 5 meters.
3. Parameters above may be modified as product improvement. We keep the right to change the product
specifications without prior notice, please take the parameters listed on the nameplate as criterion.
Summary of Contents for AL-H18/4DR1(U)
Page 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Page 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Page 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Page 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Page 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Page 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Page 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Page 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Page 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Page 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Page 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Page 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Page 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Page 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Page 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Page 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Page 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Page 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Page 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Page 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Page 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Page 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Page 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...