AUKS DC Inverter 1 Drive1 50HZ R410A Four-way cassette
11
2. Specification
Model
Indoor
ALCA-H18/4DR1
ALCA-H24/4DR1
ALCA-H36/4DR1
Panel
MB13
MB12
MB12
Outdoor
AL-H18/4DR1(U)
AL-H24/4DR1(U)
AL-H36/4DR1(U)
Power Supply
V~,Hz,
Ph
220~240,50,1
220~240,50,1
220~240,50,1
Capacity
Cooling
Btu/h
20000-18000-5500
26500-24000-7200
40000-36000-10800
W
5610-5100-1530
7920-7200-2160
11000-10000-3000
Heating
Btu/h
20140-19000-4750
29700-27000-6750
43125-37500-11250
W
5936-5600-1400
8690-7900-1975
13225-11500-3450
Electric
Data
Rated Cooling Power Input
W
2053-1579-474
2880-2215-665
4012-3086-926
Rated Heating Power Input
W
2011-1547-464
2813-2164-649
4118-3168-950
Rated Cooling Current
A
9.81-7.55-2.25
13.78-10.60-3.21
19.19-14.77-4.45
Rated Heating Current
A
9.62-7.40-2.20
13.44-10.36-3.11
19.71-15.16-4.55
Performan
ce
EER
W/W
3.23
3.25
3.24
COP
W/W
3.62
3.65
3.63
Indoor Fan
Motor
Model
YDK30-6E1
XD30A
YDK45-6 Q
Brand
Sinjun
Sinjun
Sinjun
Output Power x Fan
quantity
W
30×1
30×1
45×1
Capacitor
uF
2.5
3
4
Speed (Hi/Mi/Lo)
r/min
920/850/750
500/430/320
650/520/450
Indoor Coil
a.Number Of Row
2
2
2
b.Tube Pitch(a)x Row
Pitch(b)
mm
20.5×12.7
20.5×12.7
20.5×12.7
c.Fin Pitch
mm
1.5
1.6
1.4
d.Fin Material
Hydrophilic
aluminum fin
Hydrophilic
aluminum fin
Hydrophilic
aluminum fin
e.Tube Outside Dia.and
Material
mm
φ7
,
Inner grooved
φ7
,
Inner grooved
φ7
,
Inner grooved
f.Coil Length x Height x
Width
mm
1160×184.5×25.4
2014×205×25.4
2014×205×25.4
g.Heat Exchanging Area
m
2
5.76
9.43
12.00
Indoor
Unit
Indoor Air Flow (Hi/Mi/Lo)
m
3
/h
850/680/595
1100/880/770
1500/1200/1050
Noise Level(Hi/Mi/Lo)
dB(A)
41/38/32
45/42/36
48/45/39
Net Dimension (W*H*D)
mm
615×615×263
835×835×250
835×835×250
Packing Dimension
(W*H*D)
mm
700×690×330
900×900×330
900×900×330
Net Weight
Kg
18
24
24
Gross Weight
Kg
22
27.5
27.5
Panel
Net Dimension (W*H*D)
mm
650×650×55
950×950×55
950×950×55
Summary of Contents for AL-H18/4DR1(U)
Page 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Page 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Page 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Page 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Page 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Page 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Page 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Page 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Page 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Page 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Page 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Page 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Page 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Page 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Page 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Page 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Page 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Page 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Page 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Page 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Page 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Page 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Page 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...