background image

SS-ABGMEC80/ABGCEC80

www.abcoolairhvac.com

8/20

Supersedes 10/19

Two-Stage, Multi-Speed ECM 

Gas Furnace

80% AFUE

GMEC80 / GCEC80 

Heating Input:   40,000–120,000 BTU/h

Standard Features

•  Two-stage gas valve provides quiet,  

economical heating 

• 

Efficient and quiet multi-speed ECM circulator motor

•  SureStart® Silicon Nitride igniter  

designed for long igniter life

• 

Self-diagnostic control board 

•  Low constant fan speed circulates air  

throughout the home 

• 

Quiet, two-speed induced draft blower

• 

California Low NOx emissions-compliant 

 

models available

• 

Can no longer be installed in California’s 

South Coast Air Quality Management District 

(SCAQMD) on or after October 1, 2019.

   

• 

AHRI Certified; ETL Listed

Cabinet Features

• 

Fully insulated, heavy-gauge steel cabinet 

with durable baked-enamel finish

• 

Multi-position installation: 

 

GMEC80: upflow, horizontal left or right

 

GCEC80: downflow, horizontal left or right

• 

Removable bottom for side- or 

 

bottom-return applications

• 

Convenient left or right connection 

 

for gas/electric service

• 

Cabinet air leakage ≤ 2%

• 

Coil and furnace fit flush 

for most installations

LIFETIME

HEAT

 

EXCHANGER

LIMITED WARRANTY

*

10

YEAR

 

UNIT

 

REPLACEMENT

LIMITED WARRANTY

*

10

YEAR

 

PARTS

LIMITED WARRANTY

*

* Complete warranty details available from your local dealer or at www.abcoolairhvac.com. To receive 

the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year 

Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be 

completed within 60 days of installation. Online registration is not required in California or Québec.

Contents

Nomenclature

 ........................................ 2

Product Specifications ...........................

3

Dimensions ............................................

5

Accessories ............................................

6

Airflow Data ...........................................

7

Wiring Diagram  ................................... 24 

Summary of Contents for GMEC80 Series

Page 1: ...th durable baked enamel finish Multi position installation GMEC80 upflow horizontal left or right GCEC80 downflow horizontal left or right Removable bottom for side or bottom return applications Conve...

Page 2: ...M Upflow Horizontal N Natural Gas C Downflow Horizontal X Low NOx Motor Cabinet Width V Variable Speed ECM ComfortBridge A 14 C 21 E Multi Speed ECM S Single Speed B 17 D 24 Gas Valve Maximum CFM M M...

Page 3: ...50 40 70 40 70 Circulator Blower Size D x W 10 x 6 10 x 6 10 x 8 10 x 8 10 x 10 10 x 10 10 x 10 11 x 10 10 x 10 10 x 10 11 x 10 Horsepower RPM 1 2 1 2 1 2 1 2 3 4 3 4 3 4 3 4 3 4 1 1 Speed 5 5 5 5 5 5...

Page 4: ...3 4 1 Speed 5 5 5 5 5 5 Vent Diameter 4 4 4 4 4 4 No of Burners 3 3 3 4 4 5 Electrical Data Min Circuit Ampacity 8 7 8 7 8 7 12 45 15 32 15 32 Max Overcurrent Device amps 15 15 15 15 20 20 Ship Weight...

Page 5: ...el Gas Code NFPA 54 ANSI Z223 1 In Canada the Canada National Standard of Canada CAN CSA B149 1 and CAN CSA B142 2 GMEC80 Dimensions Model Dimensions W D H GMEC800403A 14 28 33 GMEC800603A 14 28 33 GM...

Page 6: ...ned in the Installation Manual for additional venting requirements Model Dimensions W D H GCEC800403A 14 28 33 GCEC800603A 14 28 33 GCEC800603B 17 28 33 GCEC800804B 17 28 33 GCEC800805C 21 28 33 GCEC8...

Page 7: ...OUS FAN DIP Switches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 591 568 518 463 411 355 300 243 ON OFF OFF G 1104 1058 1020 1022 10...

Page 8: ...S FAN DIP Switches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 716 647 592 541 478 420 368 296 ON OFF OFF G 1054 1002 951 906 861 82...

Page 9: ...FAN DIP Switches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1025 850 754 670 594 520 443 366 ON OFF OFF G 1258 1179 1115 1030 954 8...

Page 10: ...S FAN DIP Switches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1040 973 936 918 859 805 770 720 ON OFF OFF G 1401 1366 1320 1278 123...

Page 11: ...DIP Switches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1175 1098 1024 947 883 823 764 703 ON OFF OFF G 1547 1506 1474 1442 1390 13...

Page 12: ...1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1626 1574 1524 1479 1433 1410 1400 1358 ON OFF OFF G 2169 2116 2070 2038 2003 1970 1933 1897 ON ON OFF G 803 71...

Page 13: ...4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 553 496 436 372 308 252 198 N A ON OFF OFF G 750 703 651 600 553 504 456 409 ON ON OFF G 923 865 824...

Page 14: ...OUS FAN DIP Switches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1079 1019 975 934 890 850 808 791 ON OFF OFF G 1328 1274 1231 1191...

Page 15: ...DIP Switches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1155 1100 1048 1002 952 907 861 816 ON OFF OFF G 1418 1376 1333 1288 1248...

Page 16: ...ATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1133 1009 956 903 856 804 774 722 ON OFF OFF G 1402 1358 1317 1274 1234 1195 1154 1113 ON ON OFF G 706 63...

Page 17: ...FAN DIP Switches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1130 1071 1027 973 922 870 817 787 ON OFF OFF G 1408 1369 1319 1282 124...

Page 18: ...4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1352 1281 1218 1152 1076 1026 964 901 ON OFF OFF G 1669 1595 1527 1463 1407 1363 1336 1289 ON ON OFF...

Page 19: ...FAN DIP Switches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1450 1382 1314 1243 1181 1115 1047 973 ON OFF OFF G 1886 1822 1758 1701...

Page 20: ...0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1436 1402 1362 1313 1244 1182 1132 1079 ON OFF OFF G 1782 1744 1715 1700 1660 1619 1579 1510 ON ON OFF G 1171...

Page 21: ...ches S2 2 S2 3 S2 4 STATIC 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1424 1378 1330 1274 1226 1172 1119 1071 ON OFF OFF G 1810 1764 1718 1682 1633 1596...

Page 22: ...1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 T STAT CALL CFM CFM CFM CFM CFM CFM CFM CFM OFF OFF OFF G 1381 1324 1274 1220 1164 1137 1109 1049 ON OFF OFF G 1831 1770 1723 1677 1630 1590 1547 1506 ON ON OFF G 815 74...

Page 23: ...OUTPUT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 C...

Page 24: ...RVICING WIRING EQUIPMENT GND INTERNAL TO SWITCH PRESSURE HIGH FIRE PROT DEVICE INTEGRATED CONTROL PK PU PLUG CONNECTION 2 4 BK C DOOR OPEN OPEN WHEN DOOR SWITCH COMPARTMENT BLOWER SWITCH TEMP GND 1 BL...

Reviews: