AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling & Floor Type
53
39
16444007000003
加长轴
Motor lengthen axes
1
40
16421002000011
轴承固定座
Bearing base
1
41
16421002000219
橡胶轴承压板
Bearing top cover
1
42
16421002000219
橡胶轴承
Rubber bearings
1
43
11222023000333
R
显示灯板
SX-DISP(ZDJ)-02-SYE1
Display board
1
44
16420017000002
显示盒
Display board cover
1
45
16420013000016
面板
Front panel
1
ALCF-H48/5DR1, ALCF-H60/5DR1
N0.
BOM Code
Chinese name
Part Name
Quantity
1
16420012000002
滤网
Air-inlet filter
2
2
16420010000002
格栅
Air-inlet grill(white)
2
3
16420012000003
中滤网
In the center filter net
2
4
16420010000003
中格栅
Air-inlet grill(white)
2
5
16420015000002
左装饰板
Left side adornment plank
1
6
16421038000207
电控盒
The electricity controls a box
1
7
16421038000208
电控盒盖
The electricity controls a box
of cover
1
8
11220544000008
压线座 双联
Compress tightly electric
wire seat
1
压线盖 双联
Compress tightly electric
wire cover
1
Summary of Contents for AL-H18/4DR1(U)
Page 1: ...AUKS DC Inverter 1 Drive1 50HZ R410A 1 Service manual DC Inverter 1 Drive 1 50Hz R410a...
Page 5: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 5...
Page 7: ...AUKS DC Inverter 1 Drive1 50HZ R410A General description 7...
Page 21: ...AUKS DC Inverter 1 Drive1 50HZ R410A Four way cassette 21 Introduction of control board socket...
Page 55: ...AUKS DC Inverter 1 Drive1 50HZ R410A Ceiling Floor Type 55...
Page 89: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 89 AL H48 5DR1 U AL H60 5DR1 U...
Page 92: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 92 Filter board...
Page 109: ...AUKS DC Inverter 1 Drive1 50HZ R410A Universal outdoor unit 109...
Page 121: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 121 Outdoor protection phase sequence...
Page 122: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 122 Cooling high pressure protection...
Page 123: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 123 Heating high pressure protection...
Page 124: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 124 Cooling low pressure protection...
Page 125: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 125 Heating low pressure protection...
Page 129: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 129 Sensor failure protection...
Page 131: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 131 Poor effect...
Page 132: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 132...
Page 133: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 133 Abnormal sound or viberation...
Page 134: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 134...
Page 135: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 135 Abnormal odor...
Page 137: ...AUKS DC Inverter 1 Drive1 50HZ R410A Trouble shooting 137 Air conditioner water leakage...
Page 147: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 147 Wired controller XK 05...
Page 148: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 148...
Page 149: ...AUKS DC Inverter 1 Drive1 50HZ R410A Controller 149 Installation of wired controller...