background image

Owner’s 

Manual

WALL MOUNTED AIR CONDITIONER

KS09 | KS12 | KS18  
KS24 | KS28

KS Series

J3499_Kaden_Owners Manual_240817_V3.indd   1

28/08/2017   8:59 AM

Summary of Contents for KS09

Page 1: ...Owner s Manual WALL MOUNTED AIR CONDITIONER KS09 KS12 KS18 KS24 KS28 KS Series J3499_Kaden_Owners Manual_240817_V3 indd 1 28 08 2017 8 59 AM...

Page 2: ...mote 9 4 Care and Maintenance 10 5 Troubleshooting 12 Important note Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future r...

Page 3: ...onal to install this air conditioner Inappropriate installation may cause water leakage electric shock or fire All repairs maintenance and relocation of this unit must be performed by a licensed servi...

Page 4: ...cause electrical shock Do not clean the air conditioner with excessive amounts of water Do not clean the air conditioner with combustible cleaning agents Combustible cleaning agents can cause fire or...

Page 5: ...f when defrosting when anti cold air feature is turned on when unit is self cleaning when freeze protection is turned on when Wireless Control feature is activated Display Code Meanings In Fan mode th...

Page 6: ...perations must be carried out by a professional Louver Angle Memory When turning on your unit the louver will automatically resume its former angle Refrigerant Leakage Detection The indoor unit will a...

Page 7: ...zontal SWING button once to activate the louvre Each time you press the button it will adjust the louvre by 6 Press the button until the direction you prefer is reached 2 To make the louvre swing side...

Page 8: ...y 1 C after 1 hour and will increase an additional 1 C after another hour When in HEAT mode the unit will decrease the temperature by 1 C after 1 hour and will decrease an additional 1 C after another...

Page 9: ...nually with the MANUAL CONTROL button located on the indoor unit Note that manual operation is not a long term solution and that operating the unit with your remote control is strongly recommended BEF...

Page 10: ...light 6 When dry slide it back into the indoor unit Cleaning Your Indoor Unit Cleaning Your Air Filter CAUTION Only use a soft dry cloth to wipe the unit clean If the unit is especially dirty you can...

Page 11: ...the power Remove batteries from remote control CAUTION Before changing the filter or cleaning turn off the unit and disconnect its power supply When removing filter do not touch metal parts in the un...

Page 12: ...erature fluctuates again The indoor unit emits white mist In humid regions a large temperature difference between the room s air and the conditioned air can cause white mist Both the indoor and outdoo...

Page 13: ...be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emits a bad odor The unit may absorb odors from the environment such as fur...

Page 14: ...either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Excessive heat...

Page 15: ...qualified service technician Poor heating performance The outdoor temperature is extremely low Use other heating device Cold air is entering through doors and windows Make sure that all doors and win...

Page 16: ...J3499_Kaden_Owners Manual_240817_V3 indd 16 28 08 2017 8 59 AM...