341
7679H–CAN–08/08
AT90CAN32/64/128
25.5.4
Parameters
Table 25-9.
XA1 and XA0 Coding
XA1
XA0
Action when XTAL1 is Pulsed
0
0
Load Flash or EEPROM Address (High or low address byte determined by BS1).
0
1
Load Data (High or Low data byte for Flash determined by BS1).
1
0
Load Command
1
1
No Action, Idle
Table 25-10.
Command Byte Bit Coding
Command Byte
Command Executed
1000 0000
Chip Erase
0100 0000
Write Fuse bits
0010 0000
Write Lock bits
0001 0000
Write Flash
0001 0001
Write EEPROM
0000 1000
Read Signature bytes and Calibration byte
0000 0100
Read Fuse and Lock bits
0000 0010
Read Flash
0000 0011
Read EEPROM
Table 25-11.
No. of Words in a Page and No. of Pages in the Flash
Device
Flash Size
Page Size
PCWORD
No. of Pages
PCPAGE
PCMSB
AT90CAN32
16K words
128 words
PC[6:0]
128
PC[13:7]
13
AT90CAN64
32K words
128 words
PC[6:0]
256
PC[14:7]
14
AT90CAN128
64K words
128 words
PC[6:0]
512
PC[15:7]
15
Table 25-12.
No. of Words in a Page and No. of Pages in the EEPROM
Device
EEPROM Size
Page Size
PCWORD
No. of Pages
PCPAGE
EEAMSB
AT90CAN32
1K bytes
8 bytes
EEA[2:0]
128
EEA[9:3]
9
AT90CAN64
2K bytes
8 bytes
EEA[2:0]
256
EEA[10:3]
10
AT90CAN128
4K bytes
8 bytes
EEA[2:0]
512
EEA[11:3]
11