61
5.2.5. Results
At the end of a test sequence or single step test, you may review the measurements of each test
by pressing “<more>” and then pressing “Results”. The Results screen will appear as follow:
0 1 - 7 A C W F F A I L
0 1 - 8 D C W P M a x L i m i t
^
0 2 - 1 A C W F
S e t t i n g s R e s u l t s
0 2 - 2 D C W F 1 . 0 0 k V 1 . 0 0 k V
v
0 2 - 3 I R F 1 0 . 0 0 m A T 1 0 . 4 5 m A T
0 2 - 4 C o n t A 1 . 0 0 m A T 1 . 0 0 m A R
1 . 0 S 1 . 0 s
Using the up and down arrow keys, scroll the highlighted area to the step results you wish to
review. When the highlighted area is on the step you are reviewing, the test settings and results
will appear on the right half of the display.
5.3. Perform Tests Metering
Each test performed by the HypotULTRA III contains a unique set of parameters and therefore
requires specialized metering for each test. The following table describes what meters will be
displayed for each of the different test types.
Test Type
Real Current
Total
Current Voltage Time Resistance
AC Withstand
X
X
X
X
NA
DC Withstand
NA
X
X
X
NA
IR
NA
NA
X
X
X
Continuity
NA
NA
NA
X
X
5.3.1. Real Current Display
The AC Real Current function allows the operator to view both real and total current
simultaneously. The Display parameter (refer to
4.3.2 AC Withstand
parameter section of this
manual) allows you to select which meter will display the real and total current. When the
display parameter is set for Total, the large current meter will display the total current and the
real current will be displayed in the small current meter below the Memory name. The opposite
is true when the display parameter is set for Real.
A C W T o t a l S e t t i n g s M e m N a m e * *
M 5 0 - 8 _
P
9 9 9 . 9 s 1 0 . 0 0 m A R
M e m o r y
S t e p
E d i t
< m o r e >
Small Current Meter
Summary of Contents for HYPOTULTRA III 7620
Page 7: ......
Page 8: ......
Page 130: ...122 configure it through the drive s properties in Windows ...