Differential Commands
293
Differential Commands
REM: Set Receiver in Differential Remote Station Mode
$PASHS,RTC,REM,c1
This command sets the DG16 to operate as an RTCM differential remote station.
The c1 parameter designates the input port (A or B) for differential corrections. You
can view the current RTCM mode setting by entering the
$PASHQ,RTC
command
and checking the MODE field.
Example
Enter the following command to set receiver as a differential remote station with
port B designated as the input port for RTCM differential corrections:
$PASHS,RTC,REM,B
RPS: Rover Parameters
$PASHQ,RTC,RPS,c1
This command queries RTCM Rover parameters, where c1 is the optional port
designator for the output of the response. If a port is not specified, the receiver
sends the response to the current port.
$PASHR,RPS
The response is in the format:
$PASHR,RTC,RPS,h1,h2,h3,h4,h5,h6,h7
where Table 9.2 outlines the parameters
Table 9.2.
$PASHR,RTC,RPS Response Format
Parameter
Description
Range
h1
Mode of operation
0—Base Mode
1—Remote Mode
h2
Port used fro RTCM input
A, B, or C
h3
Remote Station ID
0 to 1027
h4
Auto-differential
N or Y
h5
QA factor setting
0 to 99
h6
Maximum age setting
0 to 999
h7
Sequence checking
N or Y
Summary of Contents for DG14
Page 12: ...xii DG16 Board Sensor Reference Manual...
Page 14: ...xiv G12 GPS OEM Board Sensor Reference Manual...
Page 48: ...28 DG14 and DG16 Board Sensor Reference Manual...
Page 72: ...52 DG14 and DG16 Board Sensor Reference Manual...
Page 202: ...182 DG14 and DG16 Board Sensor Reference Manual...
Page 344: ...324 DG14 and DG16 Board Sensor Reference Manual...
Page 374: ...354 DG14 and DG16 Board Sensor Reference Manual...
Page 389: ...369 Index W warm start 2 33 WGS 72 81 WGS 84 4 81 86 X XMG 284 XYZ 221 Z ZDA 285...
Page 390: ...370 DG14 and DG16 Board Sensor Reference Manual...