Introduction
Centellis 2100 Shelf Release 3.0 Installation and Use (6806800T37D)
57
The shelf management system consists of several major components:
Distributed intelligent platform management controllers (IPMCs) which manage and
monitor the operation and environment conditions of each field replaceable unit (FRU) in
the shelf
Shelf manager which implements a system management interface and contains shelf
management controller (ShMC) through which it communicates with other IPMCs
Intelligent platform management interface (IPMI) infrastructure which provides
communication, management, and control paths among the distributed controllers and
to the shelf manager. The IPMI infrastructure is fully compliant to the
IPMI V.1.5
and
AdvancedTCA Specification
.
The shelf manager is the active instance of the software running on the ATCA-MF106 board.
For a detailed description refer to the
ATCA-MF106 Installation and Use
guide. For a description
of the HPI-B software refer to the
System Management Interface Based on HPI-B (Centellis CO
31kX/4100/2000) User’s Guide
.
Due to high availability software, utilizing redundant hardware components, system high
availability is ensured. Shelf management software runs on two redundant ATCA-MF106
boards.
The shelf manager performs the following main tasks:
Retrieving FRU inventory information
Receiving events from sensors of the shelf
Monitoring and controlling the temperature of the shelf
Reporting of errors
Executing corrective actions
Managing blades for hot swap functionality
1.4
System Management
The system manager function is provided by the end user and is responsible for managing one
or more Centellis 2100 shelves. The shelf manager of the ATCA-MF106 board provides an
interface (Hardware Platform Interface, HPI) to monitor and control the assigned shelves.
Summary of Contents for Centellis 2100 Shelf Release 3.0
Page 1: ...Centellis 2100 Shelf Release 3 0 Installation and Use P N 6806800T37D August 2017...
Page 8: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Contents 8 Contents Contents...
Page 10: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 10 List of Tables...
Page 12: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 12 List of Figures...
Page 32: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Safety Notes 32...
Page 46: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Sicherheitshinweise 46...
Page 66: ...Introduction Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 66...
Page 112: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 112...
Page 124: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 124...
Page 132: ...Cooling Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 132...
Page 140: ...Power Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 140...
Page 174: ...Redundancy Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 174...
Page 186: ...Troubleshooting Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 186...
Page 188: ...Related Documentation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 188...
Page 189: ......