Network Management and System Access
Centellis 2100 Shelf Release 3.0 Installation and Use (6806800T37D)
151
*change Shelf Address and Shelf Entity Path setting:
shm9s8:~ #
hpishaddr -b "0700000000000000000000000000000000000000"
07 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 --
shelf address: 7
shelf entity-path: {ADVANCEDTCA_CHASSIS,7}
8.2.3.2
Backplane Interfaces
The IP address of the shelf manager backplane interfaces are created from the information in
the second IP connection record. Since these addresses are reachable through the hub from
outside the shelf, they must be different for different shelves. Therefore, the shelf geographical
address is used as third octet of the IP address. To allow for different network setups, different
network address schemes are used depending on the netmask found in the shelf manager IP
connection record.
The schemes are based on the following rules:
Use different IP networks for interface 1, interface 2 and virtual address.
In class A and class B networks, use shelf geographical address as third octet.
Use shelf manager hardware address as fourth octet.
Physical IP Address on Backplane Interface 1
Netmask of IP2
Physical IP Address
Default Value
255.0.0.0
<IP2_1 + 1>.<IP2_2>.<SGA>.<HW>
172.17.0.8,
172.17.0.9
255.255.0.0
<IP2_1>.<IP2_2 + 1>.<SGA>.<HW>
255.255.255.0
<IP2_1>.<IP2_2>.<IP2_3 + 1>.<HW>
Summary of Contents for Centellis 2100 Shelf Release 3.0
Page 1: ...Centellis 2100 Shelf Release 3 0 Installation and Use P N 6806800T37D August 2017...
Page 8: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Contents 8 Contents Contents...
Page 10: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 10 List of Tables...
Page 12: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 12 List of Figures...
Page 32: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Safety Notes 32...
Page 46: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Sicherheitshinweise 46...
Page 66: ...Introduction Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 66...
Page 112: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 112...
Page 124: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 124...
Page 132: ...Cooling Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 132...
Page 140: ...Power Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 140...
Page 174: ...Redundancy Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 174...
Page 186: ...Troubleshooting Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 186...
Page 188: ...Related Documentation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 188...
Page 189: ......