The physical address describes the physical location of an FRU in the shelf. This location is
required when an operator has to handle an FRU, for example, exchange the AdvancedTCA
blade #2. The physical address and the physical slot number are identical for AdvancedTCA
blades. The physical addresses of other FRUs like fan trays identify the type of the FRU and a
particular FRU of that type.
The lower slot has the physical slot number 1 and the upper slot has the physical slot number
2. The shelf FRU ROM provides a mapping of physical slot numbers to logical slot numbers for
each slot.
Every slot has a unique logical slot number. These logical slot numbers are used to determine
the channel mapping between the slots according to the
AdvancedTCA specification PICMG 3.0,
chapter 6.5.6
.
The table below shows the physical and logical slot numbering, IPMB addresses and hardware
addresses in a Centellis 2100 system.
Table 8-1 Slot Numbering and Slot Addresses
Device#
Hardware
Address
IPMB
Address
Logical Slot
Number
MF106 1
8
10
-
MF106 2
9
12
-
Front Blade 1
4D
9A
13
Front Blade 2
4E
9C
14
PSU 1
60
C0
-
PSU 2
61
C2
-
Rear Fan Tray
64
C8
-
Front Fan Tray
65
CA
-
User Card 1
69
D2
-
User Card 2
68
D0
-
Summary of Contents for Centellis 2100 Shelf Release 3.0
Page 1: ...Centellis 2100 Shelf Release 3 0 Installation and Use P N 6806800T37D August 2017...
Page 8: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Contents 8 Contents Contents...
Page 10: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 10 List of Tables...
Page 12: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 12 List of Figures...
Page 32: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Safety Notes 32...
Page 46: ...Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D Sicherheitshinweise 46...
Page 66: ...Introduction Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 66...
Page 112: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 112...
Page 124: ...FRU Installation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 124...
Page 132: ...Cooling Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 132...
Page 140: ...Power Subsystem Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 140...
Page 174: ...Redundancy Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 174...
Page 186: ...Troubleshooting Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 186...
Page 188: ...Related Documentation Centellis 2100 Shelf Release 3 0 Installation and Use 6806800T37D 188...
Page 189: ......