User and Programming Manual
XDS Series
77
Resolution for Symptom 2
Execute the suggested procedure to resolve symptom 1 first. If an occasional error continues to
occur while slewing the voltage or frequency slider controls in the XDSGUI program, increase the
command delay paramter located in the System, Interface dialog. The default value for the CmdDelay
is set to 30 and is displayed below the command line of the Interface window. Change this value to
40 by entering the new value from the keyboard.
Try to connect again. You may have to cycle the power on the power supply if it still shows the Err -
100 display.
Higher values than 40 may be set for the CmdDelay parameter if this fix does not resolve your
problem.
Summary of Contents for XDS 100-100
Page 4: ...User and Programming Manual 4 XDS Series Electrical Safety Symbols Used in This Manual ...
Page 27: ...User and Programming Manual XDS Series 27 Figure 3 5 Outline Drawing XDS DC Supply ...
Page 41: ...User and Programming Manual XDS Series 41 Figure 5 4 Parallel Cable Interconnect Accessory ...
Page 69: ...User and Programming Manual XDS Series 69 Figure 8 3 Replaceable Fuse Locations ...