8 Service
8.1 General
This section describes suggested maintenance and troubleshooting procedures. The
troubleshooting procedure is divided into two sections. The first section deals with basic operation
and connection of the equipment. The second section requires opening the unit and using the LED
indicators and a simple multi meter to troubleshoot the unit down to the module level. Only a
qualified electronic technician should attempt this level of troubleshooting.
8.2 Basic
Operation
Table 8-1: Basic Symptoms
PARAGRAPH
PROBLEM
8.2.1 Poor
Output Voltage Accuracy
8.2.2 Poor
Output Voltage Regulation
8.2.3
No Output and no lights on front panel
8.2.4
No output but “Display” on front panel is on
8.2.5 Error
-300
8.2.6
Can’t program DC supply on GPIB or RS232
8.2.1
Poor Output Voltage Accuracy
If the power supply exhibits poor programmed voltage accuracy, the following item may be at fault:
Table 8-2: Poor Output Voltage Accuracy
CAUSE
SOLUTION
The calibration is incorrect.
Calibrate the output.
8.2.2
Poor Output Voltage Regulation
If the AC Power supply exhibits poor voltage regulation the following item may be at fault:
Table 8-3: Poor Output Voltage Regulation
CAUSE
SOLUTION
The Remote Sense lines are not
connected at the same point monitored by
the external voltmeter used for load
regulation check.
Connect DC voltmeter to Remote Sense
lines on the Rear Panel Power Output
terminal strip.
The External voltage sense connection is
open.
Check the sense connections. Make sure
not to reverse the sense polarity or
damage to the unit may occur.
Summary of Contents for XDS 100-100
Page 4: ...User and Programming Manual 4 XDS Series Electrical Safety Symbols Used in This Manual ...
Page 27: ...User and Programming Manual XDS Series 27 Figure 3 5 Outline Drawing XDS DC Supply ...
Page 41: ...User and Programming Manual XDS Series 41 Figure 5 4 Parallel Cable Interconnect Accessory ...