User and Programming Manual
XDS Series
91
Command Syntax
[SOURce:]CURRent:HIGH <NRf>
Parameters
0 to LIM:CURR? value.
Unit A
(amperes)
*RST
Max. Current
Examples CURR:HIGH
5
Query Syntax
CURRent:HIGH?
Returned Parameters
<NR2>
Related Commands
CURR
CURR:LOW
[SOURce:]CURRent:LOW
This command sets the minimum programmed current that will be accepted by the power supply. If a
value below this limit value is programmed, a "-200 Execution Error" will be generated.
The current limit may be set between zero and the model's capability (configuration limit) which can
be queried with the LIM:CURR? command. The low limit cannot be more than the high limit however.
The *RST state for low current limit is zero.
Command Syntax
[SOURce:]CURRent:LOW <NRf>
Parameters
0 to LIM:CURR? value.
Unit A
(amperes)
*RST
0
Examples CURR:LOW
5
Query Syntax
CURRent:LOW?
Returned Parameters
<NR2>
Related Commands
CURR
CURR:HIGH
[SOURce:]LIMit:CURRent?
This command queries the maximum current the power supply can deliver. Only the Query format of
this command is available to the user.
Command Syntax
[SOURce:]LIMit:CURRent <NRf>
Parameters
maximum current
[command protected]
Query Syntax
LIMit:CURRent?
Returned Parameters
<NR2>
[SOURce:]LIMit:VOLTage?
This command queries the maximum voltage the power supply can deliver. Only the Query format of
this command is available to the user.
Command Syntax
[SOURce:]LIMit:VOLTage<NRf>
Parameters
maximum voltage
[command protected]
Query Syntax
LIMit:VOLTage?
Returned Parameters
<NR2>
Summary of Contents for XDS 100-100
Page 4: ...User and Programming Manual 4 XDS Series Electrical Safety Symbols Used in This Manual ...
Page 27: ...User and Programming Manual XDS Series 27 Figure 3 5 Outline Drawing XDS DC Supply ...
Page 41: ...User and Programming Manual XDS Series 41 Figure 5 4 Parallel Cable Interconnect Accessory ...
Page 69: ...User and Programming Manual XDS Series 69 Figure 8 3 Replaceable Fuse Locations ...