User and Programming Manual
34 XDS
Series
4.4 Operating
Modes
The XDS Series can operate in one of two modes of operation, voltage mode or current mode
with automatic cross over.
Voltage Mode (CV) mode
In this mode of operation, the output voltage of
the DC supply is regulated as long as the
current limit set is not exceeded. If the current
limit is reached due to the load condition, the
DC supply crosses over to constant current
mode by reducing the output voltage as needed
to maintain the set current limit level.
Constant Current (CC) mode
In this mode of operation, the output current of
the DC supply is regulated as long as the
voltage set is not reached. If the output voltage
reaches the set voltage, the DC supply crosses
over to the constant voltage mode by reducing
the output current as needed to maintain the set
voltage level.
The currently active mode is always indicated by the CV and CC status LED's on the front panel
and may also be queried through he remote control interface. The mode can not be changed by
the user. It is determined by the load condition and the programmed values for voltage and
current limit.