User and Programming Manual
14 XDS
Series
XDS 600-8
XDS 600-17
XDS 600-25
5
10
15
600
600
600
8.33
17
25
250 mV
250 mV
250 mV
2 V
2 V
2 V
2.1.6 Output
Current
Current Range:
See section 2.1.5
Current Programming:
Accuracy: Accuracy shown in last column as % of Full Scale (FS) from 100
% programmed to 0% programmed.
Resolution: Shown in column 3 by model.
Model
Range
Resolution
Accuracy
XDS 30-167
XDS 30-333
XDS 30-500
0 - 167 A
0 - 333 A
0 - 500 A
0.1 A
0.1 A
0.2 A
0.5 %
XDS 40-125
XDS 40-250
XDS 40-375
0 - 125 A
0 - 250 A
0 - 375 A
0.1 A
0.1 A
0.2 A
0.5 %
XDS 50-100
XDS 50-200
XDS 50-300
0 - 125 A
0 - 250 A
0 - 375 A
0.1 A
0.1 A
0.1 A
0.5 %
XDS 80-62
XDS 80-125
XDS 80-187
0 - 62.5 A
0 - 125 A
0 - 187.5 A
0.02 A
0.1 A
0.1 A
0.5 %
XDS 100-50
XDS 100-100
XDS 100-150
0 - 50 A
0 - 100 A
0 - 150 A
0.02 A
0.1 A
0.1 A
0.5 %
XDS 150-33
XDS 150-66
XDS 150-100
0 - 33.3 A
0 - 66.7 A
0 - 100 A
0.01 A
0.02 A
0.1 A
0.5 %
XDS 250-20
XDS 250-40
XDS 250-60
0 - 20 A
0 - 40 A
0 - 60 A
0.005 A
0.01 A
0.02 A
0.5 %
XDS 300-17
XDS 300-33
XDS 300-50
0 - 16.7 A
0 - 33.3 A
0 - 50 A
0.005 A
0.01 A
0.02 A
0.5 %
XDS 400-12
XDS 400-25
XDS 400-37
0 – 12.5 A
0 – 25.0 A
0 – 37.5 A
0.005 A
0.01 A
0.02 A
0.5 %
XDS 600-8
XDS 600-17
XDS 600-25
0 - 8.3 A
0 - 16.7 A
0 - 25 A
0.003 A
0.005 A
0.01 A
0.5 %
Line Regulation:
< 0.1% of I Range
Load Regulation:
< 0.1% of I Range
Stability:
+/- 0.05% of max. rating for 8 Hrs. at fixed line, load and temp
after 30 minutes warm up period
Summary of Contents for XDS 100-100
Page 4: ...User and Programming Manual 4 XDS Series Electrical Safety Symbols Used in This Manual ...
Page 27: ...User and Programming Manual XDS Series 27 Figure 3 5 Outline Drawing XDS DC Supply ...
Page 41: ...User and Programming Manual XDS Series 41 Figure 5 4 Parallel Cable Interconnect Accessory ...
Page 69: ...User and Programming Manual XDS Series 69 Figure 8 3 Replaceable Fuse Locations ...