User and Programming Manual
54
XDS
Series
Adjustment Locations:
All adjustments are made manually on the XDS series using pots. The adjustment pots can be
accessed through opening at the front of the top cover.
Figure 7-2: Calibration Adjustments
The following tables provide a reference of the adjustment pots accessible without removing the top
cover. If the XDS unit is mounted in a cabinet system, it may be necessary to pull it forward by a few
inches to access the front part of the top cover where the adjustment pots are located. Always use
caution when sliding the unit out of a cabinet, as its weight must be properly supported.
Reference
Parameter
Type
R40
Output Voltage
Full Scale
R44
7.4 VDC Reference
Normalization
R54
Voltage Measurement
Full Scale
R60 Current
Measurement
Offset
R62
Current Measurement
Full Scale
R63
Current Limit
Full Scale
R64
Peak Current Measurement
Full Scale
R81 Volt
Measurement Offset
R87 Output
Voltage
Offset
R103
Analog Programming Input
(J22 pin 4 and J22 pin 11)
Full Scale
R107 Current
Limit
Offset