![Analog Devices ADRV9001 User Manual Download Page 268](http://html1.mh-extra.com/html/analog-devices/adrv9001/adrv9001_user-manual_2939807268.webp)
UG-1828
Preliminary Technical Data
Rev. PrC | Page 268 of 338
Figure 258. Shielding of Rx Launches
RF IO baluns are spaced and aligned to reduce magnetic coupling from the structures in the balun package. Care must also be taken to
reduce cross talk over shared grounds between baluns. Another precaution taken involved placing and orienting SMA connectors to
minimize connector to connector coupling between ports.
24159-