Configuring Communication
24
NXD-700i & NXT-CA7 7” Modero Touch Panels
8.
Obtain the System Number and Master IP Address from NetLinx Studio. This information must be
specific for the system used with the configured Modero panel.
9.
Press the
Front Setup Access
button for
4 seconds
to open the
Setup
page.
10.
Press the
Protected Setup
button (located on the lower-left of the panel page) to open the
Protected Setup
page.
11.
Press the
System Settings
button (located on the
Protected Setup
page) to open the
System Settings
page
(FIG. 24) and begin configuring the communication settings on the panel to match those of the target
Master.
FIG. 24
System Settings page
MAC Address from panel is factory set to a unique address
NetLinx Master’s
connection
Panel
connection
information
information
The two possible Master Connection Types available are USB or Ethernet.
A USB connection type is a direct connection from the panel’s mini-USB port to a
corresponding USB port on the PC, which is acting as a Virtual Master.
An Ethernet connection type involves indirect communication from the panel to a
Master via an Ethernet connection to the network.
It is recommended that firmware KIT files only be transferred over a direct connection
and only when the panel is connected to a power supply.
The mini-USB connector MUST be plugged into a panel that is already active before
the PC can recognize the connection and assign an appropriate USB driver.
Summary of Contents for NXD-700i
Page 4: ......
Page 12: ...viii NXD 700i NXT CA7 7 Modero Touch Panels Table of Contents...
Page 30: ...NXT CA7 Installation 18 NXD 700i NXT CA7 7 Modero Touch Panels FIG 19 RJ 45 wiring diagram...
Page 52: ...Configuring Communication 40 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 138: ...Programming 126 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 148: ...Appendix A Text Formatting Codes 136 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 151: ...Appendix B Complex Script Support 139 NXD 700i NXT CA7 7 Modero Touch Panels...