Appendix A - Text Formatting Codes
134
NXD-700i & NXT-CA7 7” Modero Touch Panels
When data overflows from a numerical field, the overflow value is added to the previous field on the chain
if
the overflow character was specified. In the above example, if the overflow flag was set, the first example will
place the "1" into the previous logical field and the second example will place "12" in the previous logical
field.
If the overflow field already contains a value, the new value will be inserted to the right of the current
characters and the overflow field will be evaluated. Overflow continues to work until a field with no overflow
value is set or no more fields remain (i.e. reached first field).
If a character is typed and that characters appear in the Next Field list, the keyboard should move the focus to
the next field. For example, when entering time, a
":"
is used as a next field character. When entering "1:2",
the 1 is entered in the current field (hours) and then the focus is moved to the next field and 2 is entered in that
field.
When entering time in a 12-hour format, entry of AM and PM is required. Instead of adding AM/PM to the
input mask specification, the AM/PM should be handled within the NetLinx code. This allows a programmer
to show/hide and provide discrete feedback for AM and PM.
Input Mask Output Examples
The following are some common input masking examples:
URL Resources
A URL can be broken into several parts. For example, the URL
http://www.amx.com/company-info-home.asp
indicates that the protocol in use is
http
(HyperText Transport Protocol) and that the information resides on a
host machine named
www.amx.com
. The image on that host machine is given an assignment name by the
program of
company-info-home.asp (Active Server Page)
.
The exact meaning of this name on the host machine is both protocol dependent and host dependent. The
information normally resides in a file, but it could be generated dynamically. This component of the URL is
called the file component, even though the information is not necessarily in a file.
A URL can optionally specify a port, which is the port number to which the TCP connection is made on the
remote host machine. If the port is not specified, the default port for the protocol is used instead. For example,
the default port for http is 80. An alternative port could be specified as: http://www.amx.com:8080/company-
info-home.asp.
Output Examples
Common Name
Input Mask
Input
IP Address Quad
[0|255]{.}
Any value from 0 to 255
Hour
[1|12]{:}
Any value from 1 to 12
Minute/Second
[0|59]{:}
Any value from 0 to 59
Frames
[0|29]{:}
Any value from 0 to 29
Phone Numbers
(999) 000-0000
(555) 555-5555
Zip Code
00000-9999
75082-4567
Any legal HTTP syntax can be used.
Summary of Contents for NXD-700i
Page 4: ......
Page 12: ...viii NXD 700i NXT CA7 7 Modero Touch Panels Table of Contents...
Page 30: ...NXT CA7 Installation 18 NXD 700i NXT CA7 7 Modero Touch Panels FIG 19 RJ 45 wiring diagram...
Page 52: ...Configuring Communication 40 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 138: ...Programming 126 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 148: ...Appendix A Text Formatting Codes 136 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 151: ...Appendix B Complex Script Support 139 NXD 700i NXT CA7 7 Modero Touch Panels...