NXD-700i - Installation
10
NXD-700i & NXT-CA7 7” Modero Touch Panels
Pre-Wall Installation of the Conduit Box
Wall Mount panels (NXDs) are contained within an outer housing (back box).
This back box is
not
removed when installing the NXD into a Conduit Box (CB-TP7).
The back box is
only
removed to gain access for the replacement of the internal components.
The CB-TP7 is an optional metallic box that is secured onto a stud/beam in a
pre-wall
setting (
where no walls
are present
). Installation procedures and configurations can vary depending on the installation environment.
This section describes the installation procedures for the most common installation scenario.
The most important thing to remember when mounting this conduit box is that the NXD-700i Mounting Tabs
must lie flush against the outside of the sheetrock (FIG. 10).
Refer to
SP-2258-02
for detailed installation dimensions.
It is recommended that you cut out the surface slightly smaller than what is outlined in the
installation drawings so that you can make any necessary cutout adjustments.
The wiring knockouts on the left side will be used for the NXD-700i Wall Mount panel connectors,
so always secure the conduit box to the stud using the Stud Mounting Holes on the right side of the
box.
1.
Rest the right Stud Mounting tabs onto the stud (keeping the knockouts on the left).
Be sure to leave enough of a gap between the stud and NXD Mounting tabs to accommodate the
installation of the drywall or sheetrock after the conduit box has been mounted. Ultimately, the Mounting
Tabs should lie flush against the outside of the sheetrock.
2.
Fasten the CB-TP7 conduit box to the stud through the holes on the right Stud Mounting tabs (FIG. 10),
using either nails or screws.
3.
Remove the wiring knockouts from the left side of the conduit box (CB-TP7) to accommodate the cables
being threaded through to the NXD touch panel (FIG. 10).
INSTALLER: LEAVE A GAP BETWEEN THE STUD AND CONDUIT BOX
MOUNTING TABS TO ACCOMMODATE THE DRYWALL or SHEETROCK.
This gap allows the installation of the drywall or sheetrock after the CB-TP7 Conduit
Box has been installed.
FIG. 10
CB-TP7 conduit box components
Stud
Stud Mounting tabs
Drywall or sheetrock
Wiring knockouts
NXD Mounting tabs
(should lie flush against
the outside of the wall)
(
must be located
on left side
)
Remember that when mounting this conduit box, the NXD mounting tabs must lie
flush against the outside of the sheetrock.
Summary of Contents for NXD-700i
Page 4: ......
Page 12: ...viii NXD 700i NXT CA7 7 Modero Touch Panels Table of Contents...
Page 30: ...NXT CA7 Installation 18 NXD 700i NXT CA7 7 Modero Touch Panels FIG 19 RJ 45 wiring diagram...
Page 52: ...Configuring Communication 40 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 138: ...Programming 126 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 148: ...Appendix A Text Formatting Codes 136 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 151: ...Appendix B Complex Script Support 139 NXD 700i NXT CA7 7 Modero Touch Panels...