Configuring Communication
35
NXD-700i & NXT-CA7 7” Modero Touch Panels
Master Connection section - NetLinx Master Ethernet IP Address - Auto Mode
In this mode, enter the System Number of the NetLinx Master. This mode instructs the Modero to search for a
Master that uses the same System Number (assigned within the
Master Connection
section) and
resides on the
same Subnet as itself.
1.
In the
System Settings
page, press the
Mode
field until the choice cycles to the word
Auto
.
2.
Press the
System Number
field to launch a Keypad and enter the value for the system number of the
NetLinx Master. This value can be obtained from the
NetLinx Studio program > OnLine Tree
of the
Workspace window.
3.
Do not alter the
IP Settings
section of the
System Settings
page, as these fields are not applicable to this
connection mode.
4.
Enter a username and password into their respective fields if the target Master has been previously
secured.
5.
Press the
Back
button to open the
Setup
page and confirm an active connection.
Using G4 Web Control to Interact with a G4 Panel
The
G4 Web Control
feature allows a PC to interact with a G4-enabled panel via the web. This feature works in
tandem with the browser-capable NetLinx Security firmware update (
build 300 or higher
). G4 Web Control is
only available with the latest Modero panel firmware. Refer to the
G4 Web Control Settings Page
section on
page 58 for more detailed information on G4 Web control.
1.
Press the
Front Setup Access
button for 3 seconds to open the
Setup
page.
2.
Press the
Protected Setup
button located on the lower-left of the panel page to open the
Protected Setup
page and display an on-screen keypad.
3.
Enter
1988
into the Keypad’s password field (
1988 is the default password
) and press
Done
when
finished.
4.
Press the
G4 WebControl
button to open the
G4 Web Control
page (FIG. 34).
The NetLinx Master and the Modero panel must both be on the same Subnet.
Verify that the NetLinx Master (ME260/64 or NI-Series) has been installed with the
latest firmware KIT file from www.amx.com. Refer to the NetLinx Master instruction
manual for more detailed information on the use of the new web-based NetLinx
Security.
Clearing Password #5, from the initial Password Setup page, removes the need to
enter the default password before accessing the Protected Setup page.
Summary of Contents for NXD-700i
Page 4: ......
Page 12: ...viii NXD 700i NXT CA7 7 Modero Touch Panels Table of Contents...
Page 30: ...NXT CA7 Installation 18 NXD 700i NXT CA7 7 Modero Touch Panels FIG 19 RJ 45 wiring diagram...
Page 52: ...Configuring Communication 40 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 138: ...Programming 126 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 148: ...Appendix A Text Formatting Codes 136 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 151: ...Appendix B Complex Script Support 139 NXD 700i NXT CA7 7 Modero Touch Panels...