Configuring Communication
32
NXD-700i & NXT-CA7 7” Modero Touch Panels
Step 3: Configure an Ethernet Connection Type
Before beginning:
1.
Verify that the panel has been configured to communicate through an Ethernet cable connected from the
panel to a valid Ethernet Hub.
2.
Verify that the NetLinx Master is receiving power and is communicating via an Ethernet connection with
the PC running NetLinx Studio.
3.
Verify that the green Ethernet LED on the rear Ethernet port on the Master is illuminated, indicating a
proper connection.
4.
Verify that the yellow LED on the rear Ethernet port on the Master is blinking, indicating communication
with the device.
5.
After the panel powers-up, press and hold the
Front Setup Access
button for 3 seconds to proceed to the
Setup
page.
6.
Select
Protected Setup
>
System Settings
(located on the lower-left) to open the
System Settings
page
(FIG. 32).
Master Connection section - Virtual Master communication over Ethernet
Before beginning:
1.
Verify that the panel has been configured to communicate through an Ethernet cable connected from the
panel to a valid Ethernet Hub.
2.
Launch NetLinx Studio (default location is
Start
>
Programs
>
AMX Control Disc
>
NetLinx Studio
).
3.
Select
Settings
>
Master Communication Settings
, from the Main menu to open the
Master
Communication Settings
dialog (FIG. 27).
When using Ethernet as the selected communication method, the NetLinx Master
must first be set up with either a Static IP or DHCP Address obtained from either
NetLinx Studio or your System Administrator.
Before commencing, verify that the NetLinx Master is using the latest available
version of its firmware.
FIG. 32
System Connection page
Obtained
from
NetLinx
Master
When configuring the panel to communicate with a Virtual Master (on your PC) via
Ethernet, the Master IP/URL field must be configured to match the IP Address of the
PC. Make sure to use the Virtual System value assigned to the Virtual Master within
NetLinx Studio.
Summary of Contents for NXD-700i
Page 4: ......
Page 12: ...viii NXD 700i NXT CA7 7 Modero Touch Panels Table of Contents...
Page 30: ...NXT CA7 Installation 18 NXD 700i NXT CA7 7 Modero Touch Panels FIG 19 RJ 45 wiring diagram...
Page 52: ...Configuring Communication 40 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 138: ...Programming 126 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 148: ...Appendix A Text Formatting Codes 136 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 151: ...Appendix B Complex Script Support 139 NXD 700i NXT CA7 7 Modero Touch Panels...