Configuring Communication
34
NXD-700i & NXT-CA7 7” Modero Touch Panels
Master Connection section - NetLinx Master Ethernet IP Address - URL Mode
In this mode, enter the System Number (
zero
for an unknown System Number) and the IP/URL of the Master
(the Master Port Number is defaulted to
1319
).
1.
In the
System Settings
page, press the
Mode
field until the choice cycles to
URL
.
By selecting
URL
, the System Number field becomes read-only (grey) because the panel pulls this
value directly from the communicating target Master, virtual or not. A Virtual Master system value
can be set within the active AMX software applications such as NetLinx Studio, TPD4, or IREdit.
2.
Press the
Master IP/URL
field to open a Keyboard and enter the Master IP Address
obtained from the
Diagnostics - Networking Address
dialog of the NetLinx Studio application.
3.
Click
Done
to accept the new value and return to the
System Connection
page.
4.
Do not alter the Master Port Number value. This is the default value used by NetLinx.
5.
Enter a username and password (
into their respective fields
) if the target Master has been previously
secured.
6.
Press the
Back
button to return to the
Protected Setup
page.
Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode
In this mode, add the Modero panel IP Address into the URL List of the Master by using NetLinx Studio. This
mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from its URL list).
1.
Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP Address
from the IP Settings of the System Connection page.
The
DHCP/Static
field, in the
IP Settings
section of the
System Settings
page, must be set to
DHCP
to get Dynamic IP information for the panel.
Press the on-screen
Reboot
(from the
Protected Setup
page) to save any changes and restart the
panel.
After power-up, press the front button for
3 seconds
to access the
Setup
page.
Navigate to the
Setup > Protected Setup > System Settings
page and note the newly obtained
Dynamic IP Address information from the
IP Settings
section. This information is then entered into
the URL List for the connected NetLinx Master.
2.
Toggle the
Type
field until
Ethernet
is selected (
from the Master Connection section of the System
Connection page
).
3.
Press the
Mode
field (to set the connection Mode) until the choice cycles to
Listen
. The
System Number
and
Master IP/URL
fields are then greyed out.
4.
Enter a username and password into their respective fields if the target Master has been previously
secured.
5.
Select the
OnLine Tree
tab from the
Workspace
window.
6.
Enter the
System
and
Device
number for the specific Master associated with the touch panel as seen in
the
OnLine Tree
tab.
7.
Click
Add
and enter the IP Address of the Modero touch panel into the
Add URL
dialog.
8.
Click
OK
to enter the IP Address and add it to the list.
9.
Click
Done
when finished adding your panel information to the list.
If the panel does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number from
within the Device Addressing dialog is correctly assigned.
Summary of Contents for NXD-700i
Page 4: ......
Page 12: ...viii NXD 700i NXT CA7 7 Modero Touch Panels Table of Contents...
Page 30: ...NXT CA7 Installation 18 NXD 700i NXT CA7 7 Modero Touch Panels FIG 19 RJ 45 wiring diagram...
Page 52: ...Configuring Communication 40 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 138: ...Programming 126 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 148: ...Appendix A Text Formatting Codes 136 NXD 700i NXT CA7 7 Modero Touch Panels...
Page 151: ...Appendix B Complex Script Support 139 NXD 700i NXT CA7 7 Modero Touch Panels...