background image

O p e r a t i o n / R e f e r e n c e   G u i d e

T o u c h   P a n e l s

7” Modero Touch Panels

NXD-700i 7” Wall/Flush Mount Touch Panel with Intercom

NXT-CA7 7” Table Top Touch Panel

L a s t   R e v i s e d :   9 / 3 0 / 2 0 1 1

Summary of Contents for NXD-700i

Page 1: ...Operation Reference Guide Touch Panels 7 Modero Touch Panels NXD 700i 7 Wall Flush Mount Touch Panel with Intercom NXT CA7 7 Table Top Touch Panel Last Revised 9 30 2011...

Page 2: ...ked on the outside of each box The RMA is valid for a 30 day period After the 30 day period the RMA will be cancelled Any shipments received not consistent with the RMA or after the RMA is cancelled w...

Page 3: ...PLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH REGARD TO THE AMX SOFTWARE THIS LIM ITED WARRANTY GIVES LICENSEE SPECIFIC LEGAL RIGHTS Any supplements or updates to the A...

Page 4: ......

Page 5: ...e Panel Into Drywall Using Expansion Clips 12 Installing the Panel Into a Flat Surface using 4 screws 14 Installing the Panel into an optional Rack Mount Kit NXA RK7 15 Ethernet RJ 45 Port Connections...

Page 6: ...Connection section NetLinx Master Ethernet IP Address Auto Mode 35 Using G4 Web Control to Interact with a G4 Panel 35 Using the NetLinx Master To Control the G4 panel 37 Upgrading Modero Firmware 41...

Page 7: ...aring the Panel Connections Log 67 Panel Statistics Page 67 Checking the Panel Statistics 69 Refreshing the Panel Statistics 69 Clearing the Panel Statistics 69 Connection Utility 69 Using the Connect...

Page 8: ...80 show sensors 80 cal light 81 Button Commands 81 ANI 81 APF 81 BAT 82 BAU 82 BCB 82 BCF 83 BCT 83 BDO 84 BFB 84 BIM 84 BMC 85 BMF 86 BMI 87 BML 87 BMP 88 BNC 88 BNN 88 BNT 88 BOP 89 BOR 89 BPP 89 BR...

Page 9: ...CB 100 BCF 100 BCT 101 BMP 101 BOP 102 BRD 102 BWW 103 FON 103 ICO 104 JSB 104 JSI 105 JST 105 TEC 106 TEF 106 Panel Runtime Operations 107 ABEEP 107 ADBEEP 107 TXT 107 AKB 108 AKEYB 108 AKEYP 108 AKE...

Page 10: ...115 BBR 115 RAF 115 RFR 115 RAF RMF Embedded Codes 116 RMF 116 RSR 116 Escape Sequences 117 DV 117 SY 117 IP 117 HN 117 MC 117 ID 117 PX 117 PY 117 ST 117 AC 117 AP 117 CC 117 CP 117 LC 117 LP 117 BX...

Page 11: ...TATE 124 PHN PRIVACY 124 PHN PRIVACY 124 PHN REDIAL 124 PHN TRANSFER 124 PHN SETUP PASSWORD 125 PHN SETUP PORT 125 PHN SETUP PROXYADDR 125 PHN SETUP STUNADDR 125 PHN SETUP USERNAME 125 Troubleshooting...

Page 12: ...viii NXD 700i NXT CA7 7 Modero Touch Panels Table of Contents...

Page 13: ...ls Overview The Modero family of 7 inch Touch Panels includes the NXD 700i and the NXT CA7 FIG 1 Product specifications for each panel is provided on the following pages FIG 1 NXD 700i and NXT CA7 7 i...

Page 14: ...40 13 90 cm x 18 40 cm x 8 64 cm Power Requirements PoE Powered No local power supply needed Max power draw 5 5W Memory 128 MB SDRAM 256MB integrated Flash Memory not upgradeable factory programmed fi...

Page 15: ...using the ICSP protocol over Ethernet LEDs show communication activity connections speeds and mode information L A link activity Yellow LED lights On when Ethernet cables are connected and terminated...

Page 16: ...e port to be used for headphone connectivity The Ethernet connector also supports Power over Ethernet POE NXT CA7 Overview The NXT CA7 FG2258 09 is an incredibly versatile user interface combining a s...

Page 17: ...s Motion Sensor PIR Passive Infrared Detector to wake the panel when panel is approached Front Bezel Button Provides both access to the Setup and Calibration pages and toggles the panel between a slee...

Page 18: ...ects the presence of a headphone adaptor allowing the port to be used for headphone connectivity The Ethernet connector also supports Power over Ethernet POE NXT CA7 Specifications Cont Operating Stor...

Page 19: ...the two small buttons and associated two clear light pipes 1 The Faceplate is secured to the panel with plastic latches To remove the Faceplate simply pull it away from the panel by gently tugging it...

Page 20: ...i unit Make sure to align the Microphone Light and PIR Motion sensor locations on the main unit to their respective openings on the Faceplate assembly Installing the Button Trim Ring The outer No Butt...

Page 21: ...y press down around the Button Trim Ring until all of the latches are securely inserted into their openings on the Faceplate and the Button Trim Ring is securely fastened Verify the Button Trim Ring i...

Page 22: ...he NXD 700i Wall Mount panel connectors so always secure the conduit box to the stud using the Stud Mounting Holes on the right side of the box 1 Rest the right Stud Mounting tabs onto the stud keepin...

Page 23: ...outs on the left of the conduit box and the connections have been tested prior to installation of the NXD 700i 1 Remove the Faceplate bezel A in FIG 11 from the main NXD unit B in FIG 11 by gripping t...

Page 24: ...As the screw is tightened the clip bends toward the insertion hole and into the wall This bending creates a grip on the wall by either pressing onto the wall or by securing the drywall between the hou...

Page 25: ...pansion clips into the cutout until the Mounting Tabs on the NXD unit lie flush against the wall 9 Tighten all three drywall clip sets screws and clips until the entire Mounting Tab is securely fasten...

Page 26: ...e the area by removing any screws or nails from the surface before beginning the cutout process 2 Cut out the surface for the NXD Wall Mount unit using the dimensions shown in FIG 14 3 Remove the Face...

Page 27: ...0i unit 2 Thread the incoming Ethernet and USB cables through the surface opening leaving enough slack in the wiring to accommodate any re positioning of the panel 3 Connect the Ethernet and USB cable...

Page 28: ...0 Base T RJ 45 connector and cable The Ethernet cable is connected to the rear of Table Top and side of the Wall Mount panels The following table lists the pinouts signals and pairing associated with...

Page 29: ...nels The following table lists the pinouts signals and pairing associated with the Ethernet connector FIG 19 diagrams the RJ 45 pinouts and signals for the Ethernet RJ 45 connector and cable It is rec...

Page 30: ...NXT CA7 Installation 18 NXD 700i NXT CA7 7 Modero Touch Panels FIG 19 RJ 45 wiring diagram...

Page 31: ...etween the PoE devices and standard power outlets by up to 328 feet 100 meters FIG 20 PS POE AF Power Over Ethernet Power Supply Each PoE Injector may be used for one device s power needs Multiple dev...

Page 32: ...nclosure EMC Information FCC Part 15 Class B EN55022 Class B Immunity ESD EN61000 4 2 RS EN61000 4 3 EFT EN61000 4 4 Surge EN61000 4 5 CS EN61000 4 6 Voltage Dip EN61000 4 11 Harmonic EN61000 3 2 CE C...

Page 33: ...button FIG 21 for 8 seconds to pass over the Setup page and access the Calibrate setup page FIG 22 Single push release puts the panel to sleep 4 Second press and hold opens the Setup Page 8 Second pre...

Page 34: ...hrough the panel s firmware this firmware page may be accessed via G4 WebControl where you can navigate to the Protected Setup page and press the Calibrate button through a VNC window This action caus...

Page 35: ...o the Protected Setup page 7 Press the on screen Reboot button to restart the panel and incorporate any changes Before commencing verify that you are using the latest NetLinx Master and Modero panel f...

Page 36: ...et Master FIG 24 System Settings page MAC Address from panel is factory set to a unique address NetLinx Master s connection Panel connection information information The two possible Master Connection...

Page 37: ...driver has been completed confirm the proper installation of the large Type A USB connector to the PC s USB port and restart the PC 2 Connect the terminal end of the Ethernet cable to the connector o...

Page 38: ...Within the Device Manager dialog the AMX USBLAN device appears under Network Adapters and has a unique name such as AMX USB LAN LINK 2 FIG 25 The number changes depending on which recognized panel is...

Page 39: ...r to the previous section for more information 2 Launch NetLinx Studio default location is Start Programs AMX Control Disc NetLinx Studio 3 Select Settings Master Communication Settings from the Main...

Page 40: ...evices on the Virtual System The default System value is one 11 Right click on the Empty Device Tree System entry and select Refresh System to re populate the list The panel will not appear as a devic...

Page 41: ...igured for USB communication and the Virtual Master setup within NetLinx Studio its now time to verify the panel is ready to receive files 3 Click the OnLine Tree tab in the Workspace window to view t...

Page 42: ...ection until the choice cycles to DHCP 4 Press the optional Host Name field to open a Keyboard and enter the Host Name information 5 Press Done after you are finished assigning the alpha numeric strin...

Page 43: ...ng the communication parameters for the target Master Step 2 Choose a Master Connection Mode Setting The Master Connection section of the System Connection page uses three Ethernet MODE settings URL i...

Page 44: ...G 32 Master Connection section Virtual Master communication over Ethernet Before beginning 1 Verify that the panel has been configured to communicate through an Ethernet cable connected from the panel...

Page 45: ...Master IP URL field on the panel 9 Click OK three times to close the open dialogs save your settings and return to the main NetLinx Studio application 10 Click the OnLine Tree tab in the Workspace win...

Page 46: ...atic IP for the Modero panel from your System Administrator or a DHCP Address from the IP Settings of the System Connection page The DHCP Static field in the IP Settings section of the System Settings...

Page 47: ...l The G4 Web Control feature allows a PC to interact with a G4 enabled panel via the web This feature works in tandem with the browser capable NetLinx Security firmware update build 300 or higher G4 W...

Page 48: ...d 8 From the Web Name keyboard enter a unique alphanumeric string to identify this panel and press Done when finished This information is used by the NetLinx Security Web Server to display on screen l...

Page 49: ...board to begin the communication process between the target Master and your computer Initially the Master Security option is disabled from within the System Security page and no username and password...

Page 50: ...ver IP Address This is the IP address of the target touch panel not the IP of the Master The IP address may be found in the System Settings page for more information please refer to the System Setting...

Page 51: ...eb Control page on the panel 11 Click OK to send the password to the panel and begin the session A confirmation message appears stating Please wait Initial screen loading The secondary window then sho...

Page 52: ...Configuring Communication 40 NXD 700i NXT CA7 7 Modero Touch Panels...

Page 53: ...the proper installation of the large Type A USB connector to the PC s USB port and restart your machine 2 After the NXD 700i NXT CA7 panel powers up press and hold the grey Front Setup Access button f...

Page 54: ...rectly with a panel Everything else such as the Authentication is greyed out because the communication is not going through the Master s UI 6 Click the Edit Settings button on the Communications Setti...

Page 55: ...unication between the Virtual Master and the panel click the OnLine Tree tab in the Workspace window FIG 42 to view the devices on the Virtual System The default System value is one 3 Right click on t...

Page 56: ...n the OnLine Tree tab of the Workspace window The Port field is greyed out 10 Click the Reboot Device checkbox This causes the touch panel to reboot after the firmware update process is complete The r...

Page 57: ...section on page 52 and the Protected Setup section on page 45 for more detailed information Setup Page The Setup page FIG 45 centers around basic Modero panel properties such as the Connection Status...

Page 58: ...tion is established with a target Master The panel must be rebooted before incorporating any panel communication changes and detecting any active Ethernet connections The Ethernet connection is only d...

Page 59: ...previously active touch panel page Wired icon The icon to the left of the Connection Status Icon displays that the current connection to the Master is Wired image of three networked computers Connecti...

Page 60: ...st Save Date Displays the last date the project was saved Blink Rate Displays the feedback blink rate 10th of second Job Comments Displays any comments associated to the job These comments are taken f...

Page 61: ...l The maximum available screen width on a NXD 500i panel is 800 pixels Screen Height Displays the pixel height being used to display the incoming signal on the Modero panel The maximum available scree...

Page 62: ...Master The Set Time Date button sets the Master to retain and save any time date modifications made on the Time Date Setup page Time Display fields These fields display the time in three formats STAND...

Page 63: ...s on the icon if the panel has established a connection with a currently secured target Master requiring a username and password Default Panel Sounds Sets the panel to play various sounds Activating t...

Page 64: ...bed in the table below Supported WAV Sampling Rates 48000 Hz 16000 Hz 44100 Hz 12000 Hz 32000 Hz 11025 Hz 24000 Hz 8000 Hz 22050 Hz FIG 51 Protected Setup Navigation Buttons FIG 52 Protected Setup pag...

Page 65: ...button located below the LCD to access the firmware pages Default condition is On Press and hold this grey button for 3 seconds to access the Setup page Press and hold this grey button for 6 seconds...

Page 66: ...indow Security Profile Features Standard Factory default shipped in this configuration Default Protected Setup Password is 1988 Remote login uses Telnet Secure Default Protected Setup Password is Amx1...

Page 67: ...er 3 consecutive unsuccessful SSH login attempts login lockout is enabled for 15 minutes Login and logout audit logging is enabled DoD login banner is enabled A transition from one security mode to an...

Page 68: ...ll Duplex 100 Half Duplex or 100 Full Duplex MAC Address Displays a read only field that is factory set by AMX for the built in Ethernet interface Master Connection Sets the NetLinx Master communicati...

Page 69: ...me Password If the target Master has been previously secured enter the alphanumeric string into each field assigned to a pre configured user profile on the Master This profile should have the pre defi...

Page 70: ...he panel s connection status regardless of what page is currently active A Lock only appears on the icon if the panel has established a connection with a currently secured target Master requiring a us...

Page 71: ...VNC Web Server s port value Default value is 5900 Maximum Number of Connections This read only field displays the maximum number of users that can be simultaneously connected to the target panel via...

Page 72: ...o RAM cache the next time they are viewed As the Flash cache approaches its maximum size the least recently used items may be discarded to make room for new items The elements of this page are as foll...

Page 73: ...f the memory available versus in use RAM Max Size The maximum amount of memory available for all image caching RAM Current Size The memory currently in use for caching static and dynamic images RAM Hi...

Page 74: ...f three networked computers Connection Status icon The icon in the upper right corner of each Setup page shows online offline state of the panel to the master Bright red disconnected Bright green conn...

Page 75: ...detected by the on board photo sensor Light Sensor Allows the user to review the Modero panel light sensor port and channel settings The Sensor Level field indicates the level used to report the ligh...

Page 76: ...air conditioner vents or moving curtains 4 Copy the movement intended to set off the Sensor while watching the Motion Sensor bar such as walking past the device In particular watch for the spikes in...

Page 77: ...ements of a particular installation SIP Settings Page Back Saves all changes and returns to the previous page Wired icon The icon to the left of the Connection Status Icon displays that the current co...

Page 78: ...o the proxy server Proxy Address This option enables you to enter the IP address or DNS name of the proxy server that you want to use to register Port Number The option displays the port you use to co...

Page 79: ...of the Connection Status Icon displays that the current connection to the Master is Wired image of three networked computers Connection Status icon The icon in the upper right corner of each Setup pag...

Page 80: ...ght green Bright yellow panel missed a blink message from the master It will remain yellow for 3 missed blink messages and then turn red It will return to green when a blink message is received Note a...

Page 81: ...the Clear button 4 Confirm the selection Connection Utility The options on the Connection Utility popup window allow you to verify connection information and statistics for the panel FIG 67 Last 15 Mi...

Page 82: ...xpects a response If it is received the button stays green If it is missed the button goes yellow After three misses 3 seconds it will go red until a response from the master is received and then it w...

Page 83: ...s for General buttons 1 Off state and 2 On state Level Range 1 600 Default level value 0 255 can be set up to 1 65535 Address port Range 1 100 These button assignments can only be adjusted in TPD4 and...

Page 84: ...ge to the named hide effect Syntax PHE popup page name hide effect name Variable popup page name 1 50 ASCII characters Name of the page the popup is displayed On hide effect name Refers to the popup e...

Page 85: ...1 Deactivates the popup page Popup1 on the current page PPG Toggle a specific popup page on either a specified page or the current page If the page name is empty the current page is used see example 2...

Page 86: ...ample 2 If the popup page is already on do not re draw it This command works in the same way as the Show Popup command in TPDesign4 Syntax PPN popup page name page name Variable popup page name 1 50 A...

Page 87: ...page name x coordinate y coordinate Variable popup page name 1 50 ASCII characters Name of the page the popup is displayed On Example SEND_COMMAND Panel PSP Popup1 100 0 Sets the Popup1 show effect x...

Page 88: ...is command works in the same way as the Toggle Popup command in TPDesign4 Syntax PPOG popup page name page name Variable popup page name 1 50 ASCII characters Name of the popup page page name 1 50 ASC...

Page 89: ...Yellow 191 191 0 65 Very Dark Magenta 95 0 95 15 Medium Yellow 159 159 0 66 Very Light Pink 255 0 128 16 Dark Yellow 127 127 0 67 Light Pink 223 0 112 17 Very Dark Yellow 95 95 0 68 Pink 191 0 96 18...

Page 90: ...8 21 Arial 12 4 Courier New 26 22 Arial 14 5 Courier New 32 23 Arial 16 6 Courier New 18 24 Arial 18 7 Courier New 26 25 Arial 20 8 Courier New 34 26 Arial 24 9 AMX Bold 14 27 Arial 36 10 AMX Bold 20...

Page 91: ...e 145 47 Diamond 125 22 Circle 155 48 Diamond 135 23 Circle 165 49 Diamond 145 24 Circle 175 50 Diamond 155 25 Circle 185 51 Diamond 165 26 Circle 195 52 Diamond 175 53 Diamond 185 97 Menu Bottom Roun...

Page 92: ...5 145 Menu Left Rounded 95 153 Menu Left Rounded 175 146 Menu Left Rounded 105 154 Menu Left Rounded 185 147 Menu Left Rounded 115 155 Menu Left Rounded 195 148 Menu Left Rounded 125 Telnet Commands s...

Page 93: ...nel during the light calibration to allow the light sensor to see maximum brightness The panel should be positioned installed and operating in the expected light conditions that the panel will be expe...

Page 94: ...On state unicode text 1 50 ASCII characters Unicode characters must be entered in Hex format Example SEND_COMMAND Panel BAU 520 1 00770062 Appends Unicode text 00770062 to the button s OFF state BCB S...

Page 95: ...500 504 510 515 1 12 SEND_COMMAND Panel BCF 500 504 510 515 1 Yellow SEND_COMMAND Panel BCF 500 504 510 515 1 F4EC0A63 SEND_COMMAND Panel BCF 500 504 510 515 1 F4EC0A Sets the Off state fill color by...

Page 96: ...om to top to Border Fill Text Icon and Image Example 2 SEND_COMMAND Panel BDO 1 0 12345 Sets all states of a button back to its default drawing order BFB Set the feedback type of the button ONLY works...

Page 97: ...source port 1 100 source address 1 4000 source state 1 256 codes BM Picture Bitmap BR Border CB Border Color CF Fill Color CT Text Color EC Text effect color EF Text effect FT Font IC Icon JB Bitmap...

Page 98: ...bitmap filename empty is clear I icon 01 9900 0 clear Set the icon using values of 01 9900 icon numbers are assigned in the TPDesign4 Resource Manager tab Slots section I icon 01 9900 0 clear Set the...

Page 99: ...he input mask of a text area VL 0 1 Log On Log Off the computer control connection VN network name Set network connection name VP password Set the network connection password Example SEND_COMMAND Pane...

Page 100: ...keNote annotations Syntax BNC vt addr range command value Variable variable text address range 1 4000 command value 0 clear 1 clear all Example SEND_COMMAND Panel BNC 973 0 Clears the annotation of th...

Page 101: ...ith a border value for those buttons with a defined address range Refer to theBorder Styles and Programming Numbers table on page 78 for more information Syntax BOR vt addr range border style name or...

Page 102: ...t focus to multiple buttons Only one variable text address can be in focus at a time Syntax BSF vt addr range selection value Variable variable text address range 1 4000 selection value Unselect 0 and...

Page 103: ...ed address Syntax BVP vt addr range network password Variable variable text address range 1 4000 network password 1 50 ASCII characters Example SEND_COMMAND Panel BVP 500 PCLOCK Sets the password to P...

Page 104: ...on from flipping to a previous page ENA Enable or disable buttons with a set variable text range Syntax ENA vt addr range command value Variable variable text address range 1 4000 command value 0 disa...

Page 105: ...500 3 Inverts the joystick axis origin to the bottom right corner GLH Change the bargraph upper limit Syntax GLH vt addr range bargraph hi Variable variable text address range 1 4000 bargraph limit ra...

Page 106: ...Variable variable text address range 1 4000 color value Refer to the RGB Values for all 88 Basic Colors table on page 77 Example SEND_COMMAND Panel GSC 500 12 Changes the bargraph or joystick slider...

Page 107: ...es for General buttons 1 Off state and 2 On state new text alignment Value of 1 9 corresponds to the following locations Example SEND_COMMAND Panel JSB 500 504 510 515 1 2 1 Sets the off on state pict...

Page 108: ...0 515 1 2 1 Sets the text alignment to the upper left corner for those buttons with variable text ranges of 500 504 510 515 MBT Set the Mouse Button mode On for the virtual PC Syntax MBT pass data Var...

Page 109: ...F Set the text effect The Text Effect is specified by name and can be found in TPD4 Syntax TEF vt addr range button states range text effect name Variable variable text address range 1 4000 button sta...

Page 110: ...to the TPDesign4 Instruction Manual for more information Text Effects Glow S Soft Drop Shadow 1 Medium Drop Shadow 1 Hard Drop Shadow 1 Glow M Soft Drop Shadow 2 Medium Drop Shadow 2 Hard Drop Shadow...

Page 111: ...CUSTOM_EVENT TP 529 1011 ON state Border Color CUSTOM_EVENT TP 529 1012 ON state Fill Color CUSTOM_EVENT TP 529 1013 ON state Text Color CUSTOM_EVENT TP 529 1014 Border Name CUSTOM_EVENT TP 529 1015 O...

Page 112: ...COMMAND Panel BCB 529 1 Gets the button OFF state border color information The result sent to the Master would be ButtonGet Id 529 Type 1011 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT 222222FF TEXT LENGTH...

Page 113: ...color information The result sent to Master would be ButtonGet Id 529 Type 1013 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT FFFFFEFF TEXT LENGTH 9 BMP Get the current bitmap name Syntax BMP vt addr range b...

Page 114: ...the Master would be ButtonGet Id 529 Type 1015 Flag 0 VALUE1 1 VALUE2 200 VALUE3 0 TEXT TEXT LENGTH 0 BRD Get the current border name Syntax BRD vt addr range button states range Variable variable te...

Page 115: ...ate word wrap flag status information The result sent to the Master would be ButtonGet Id 529 Type 1010 Flag 0 VALUE1 1 VALUE2 1 VALUE3 0 TEXT TEXT LENGTH 0 FON Get the current font index Syntax FON v...

Page 116: ...information The result sent to the Master would be ButtonGet Id 529 Type 1003 Flag 0 VALUE1 2 VALUE2 12 VALUE3 0 TEXT TEXT LENGTH 0 JSB Get the current bitmap justification Syntax JSB vt addr range bu...

Page 117: ...ification information The result sent to the Master would be ButtonGet Id 529 Type 1006 Flag 0 VALUE1 1 VALUE2 6 VALUE3 0 TEXT TEXT LENGTH 0 JST Get the current text justification Syntax JST vt addr r...

Page 118: ...information The result sent to the Master would be ButtonGet Id 529 Type 1009 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT 5088F2AE TEXT LENGTH 9 TEF Get the current text effect name Syntax TEF vt addr ran...

Page 119: ...and The reply will start at this index custom event type 1001 Flag Zero Value1 Button state number Value2 Actual length of string Value3 Index Text Text from the button Text length Button text length...

Page 120: ...Keyboard and initializes the text string This is a Test AKEYP Pop up the keypad icon and initialize the text string to that specified The keypad string is set to null on power up and is stored until...

Page 121: ...D Panel BRIT 50 Sets the brightness level to 50 BRT Set the panel brightness Syntax BRT brightness level Variable brightness level 0 100 Example SEND COMMAND Panel BRT 70 Sets the brightness level to...

Page 122: ...d Keypad displays a instead of the numbers typed The Prompt Text is optional Syntax PKP initial text prompt text Variables initial text 1 50 ASCII characters prompt text 1 50 ASCII characters Example...

Page 123: ...xt Enter Phone Number TPAGEON Turn On page tracking This command turns On page tracking whereby when the page or popups change a string is sent to the Master This string may be captured with a CREATE_...

Page 124: ...mechanism This process sends a virtual keystroke command VKS to the Master Example 2 SEND COMMAND Panel KPS 0 Disables the keyboard passthru to the Master The following point defines how the parameter...

Page 125: ...down 131 83 F1 132 84 F2 133 85 F3 134 86 F4 135 87 F5 136 88 F6 137 89 F7 138 8A F8 139 8B F9 140 8C F10 141 8D F11 142 8E F12 143 8F Num Lock 144 90 Caps Lock 145 91 Insert 146 92 Delete 147 93 Hom...

Page 126: ...el PWD Main Sets the page flip password to Main PWD Set the page flip password Password level is required and must be 1 4 Syntax PWD password level page flip password Variables password level 1 4 page...

Page 127: ...by a character any character contained in the URL must be escaped with a second character see example The file name field indicated by a F embedded code may contain special escape sequences as shown...

Page 128: ...the resource Sports_Image file name to test jpg and the path to Lab_Test Images Note that the 5F in the file path is actually encoded as 5F RSR Change the refresh rate for a given resource Syntax RSR...

Page 129: ...have pattern matching as part of their filename Neither newest file nor pattern matching apply to HTTP Dynamic Images When set the panel will first pull a list of files matching the given pattern fro...

Page 130: ...m start Starts a call to the specified IP address and ports where initial mode is either 1 talk or 0 listen or 2 both If no mode is specified 0 listen is assumed Note No data packets will actually flo...

Page 131: ...D DEV ICM LISTEN Variables None Example SEND_COMMAND TP1 ICM LISTEN ICM MICLEVEL Set the microphone level during an intercom call Syntax SEND_COMMAND DEV ICM MICLEVEL Variables MICLEVEL Range 0 100 Ex...

Page 132: ...eived AMX 38K or 455k In some cases both of these ports cannot be enabled at the same time Panel IR Commands IRM Pulses the given channel IR on for onTime in tenths of seconds Delays offTime tenths of...

Page 133: ...is connected PHN DECLINE Decline send to voice mail if configured the incoming call on CallID as indicated from the previous PHN INCOMING message CallID should be 0 or 1 Syntax PHN DECLINE CallID Vari...

Page 134: ...umber of new messages old message count The number of old messages new urgent message count The number of new messages marked urgent old urgent message count The number of old messages marked urgent E...

Page 135: ...the auto answer feature The panel responds with the PHN AUTOANSWER state message Syntax PHN AUTOANSWER Example SEND_COMMAND Panel PHN AUTOANSWER PHN CALL Calls the provided number Syntax PHN CALL num...

Page 136: ...feature The panel responds with the PHN PRIVACY state message Syntax PHN PRIVACY Example SEND_COMMAND Panel PHN PRIVACY PHN REDIAL Redials the last number Syntax PHN REDIAL Example SEND_COMMAND Panel...

Page 137: ...PORT 5060 PHN SETUP PROXYADDR Sets the IP address for the proxy server Syntax PHN SETUP PROXYADDR IP Variable IP The IP address for the proxy server Example SEND_COMMAND Panel PHN SETUP PROXYADDR 192...

Page 138: ...Programming 126 NXD 700i NXT CA7 7 Modero Touch Panels...

Page 139: ...access If prompted with a VNC Server dialog enter the IP Address of the target panel This can be found within the Setup Protected Setup System Connection page This IP Address of the panel appears wit...

Page 140: ...ppear in the list of available devices My Connection Status button isn t blinking and it says the USB is con necting USB Connecting is displayed when the panel tries to establish USB communication wit...

Page 141: ...ng the ping feature you will still attempt to make a connection but a failure will take longer to be recognized Some firewalls and networks do not allow pinging though and the ping will then always re...

Page 142: ...ms also started after downloading to a new panel or a panel with a TPD4 file that takes up a considerable amount of the available Flash memory Cause If the G4 device already contains a large enough fi...

Page 143: ...n in the table below Bargraph Text Code Inputs Code Bargraph Multi State Bargraph P Display the current percentage of the bargraph derived from the Adjusted Level Value as it falls between the Range V...

Page 144: ...characters in a text area Suggest proper format with fixed characters Right to Left Required or Optional Change Force a Case Create multiple logical fields Specify range of characters number for each...

Page 145: ...input mask is applied the behavior of the keyboard needs to change to accommodate the input mask s requirement When working with masks any literal characters in the mask will be skipped by any cursor...

Page 146: ...hide and provide discrete feedback for AM and PM Input Mask Output Examples The following are some common input masking examples URL Resources A URL can be broken into several parts For example the UR...

Page 147: ...code it replaces that code with a particular piece of panel button or state information For example http www amx com img asp device DV would become http www amx com img asp device 10001 Other used es...

Page 148: ...Appendix A Text Formatting Codes 136 NXD 700i NXT CA7 7 Modero Touch Panels...

Page 149: ...and TPDesign4 v3 1 or higher support complex script languages to the extent that the True Type font currently selected for that state supports the language in question TPDesign4 allows the user to ty...

Page 150: ...es will display for characters entered via the language bar even if the selected font supports the language Text in these languages can still be pasted via the clipboard or via the Alt Scan Code metho...

Page 151: ...Appendix B Complex Script Support 139 NXD 700i NXT CA7 7 Modero Touch Panels...

Page 152: ...egistered trademarks of AMX AMX reserves the right to alter specifications without notice at any time It s Your World Take Control 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000...

Reviews: