Programming
67
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
Page Commands (Cont.)
@PPA
Close all popups on a specified page.
• If the page name is empty, the current page is used.
• This command works in the same way as the ’Clear Page’ command in TPDesign4.
Syntax:
"'@PPA-<page name>'"
Variable:
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.
Example:
SEND_COMMAND Panel,"'@PPA-Page1'"
Close all popups on Page1.
@PPF
Deactivate a specific popup page on either a specified page or the current page.
• If the page name is empty, the current page is used (see example 2).
• If the popup page is part of a group, the whole group is deactivated.
• This command works in the same way as the ’Hide Popup’ command in TPDesign4.
Syntax:
"'@PPF-<popup page name>;<page name>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.
Example:
SEND_COMMAND Panel,"'@PPF-Popup1;Main'"
Deactivates the popup page ’Popup1’ on the Main page.
Example 2:
SEND_COMMAND Panel,"'@PPF-Popup1'"
Deactivates the popup page ’Popup1’ on the current page.
@PPG
Toggle a specific popup page on either a specified page or the current page.
Toggling refers to the activating/deactivating (On/Off) of a popup page.
• If the page name is empty, the current page is used (see example 2).
• This command works in the same way as the ’Toggle Popup’ command in TPDesign4.
Syntax:
"'@PPG-<popup page name>;<page name>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.
Example:
SEND_COMMAND Panel,"'@PPG-Popup1;Main'"
Toggles the popup page ’Popup1’ on the ’Main’ page from one state to another (On/Off).
Example 2:
SEND_COMMAND Panel,"'@PPG-Popup1'"
Toggles the popup page ’Popup1’ on the current page from one state to another (On/Off).
@PPK
Kill a specific popup page from all pages.
•
Kill
refers to the deactivating (Off) of a popup window from all pages.
• If the pop-up page is part of a group, the whole group is deactivated.
• This command works in the same way as the 'Clear Group' command in TPDesign 4.
Syntax:
"'@PPK-<popup page name>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
Example:
SEND_COMMAND Panel,"'@PPK-Popup1'"
Kills the popup page ’Popup1’ on all pages.
Summary of Contents for Modero NXD-500i
Page 4: ......
Page 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...