Configuring Communication
33
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
8.
From the
Web Name
keyboard, enter a unique alphanumeric string to identify this panel and press
Done
when
finished. This information is used by the NetLinx Security Web Server to display on-screen links to the panel.
The on-screen links use the IP Address of the panel and not the name for communication
(FIG. 29).
9.
Press the
Web Control Password
field to open the
Web Password
keyboard.
10.
From the Web Password keyboard, enter a unique alpha-numeric string to be assigned as the G4 Authentication
session password associated with VNC web access of this panel. Press Done when finished.
11.
Press the
Web Control Port
field to open the Web Port Number keypad.
12.
Within the keypad, enter a unique numeric value to be assigned to the port being used by the VNC Web Server and
press
Done
when finished. The default value is
5900
.
The remaining fields within the G4 Web Control Settings
section of this page are read-only and cannot be altered.
13.
Press the
Up/Down
arrows on either sides of the G4 Web Control
Timeout
field to increase or decrease the amount
of time the panel can remain idle (
no cursor movements
) before the session is closed and the user is disconnected.
14.
Press the
Back
button to return to the
Protected Setup
page.
15.
Press the on-screen
Reboot
button to save any changes and restart the panel.
Using the NetLinx Master to Control the G4 panel
Refer to the particular NetLinx Master’s instruction manual for detailed information on how to download the latest
firmware from
www.amx.com
.
This firmware build enables SSL certificate identification and encryption, HTTPS communication, ICSP data
encryption, and disables the ability to alter the Master security properties via a TELNET session.
Once the Master’s IP Address has been set through NetLinx Studio:
1.
Launch your web browser.
2.
Enter the IP Address of the target Master (
ex: http://198.198.99.99
) into the web browser’s
Address
field.
3.
Press the
Enter
key on your keyboard to begin the communication process between the target Master and your
computer.
Initially, the Master Security option is disabled from within the
System Security
page, and no username and
password is required for access or configuration.
FIG. 29
Sample relationship between G4 Web Control and Mange WebControl Connections window
Verify that the NetLinx Master’s IP Address and System Number have been properly
entered into the Master Connection section of the System Connection page.
In order to fully utilize the SSL encryption, your web browser should incorporate the an encryption
feature. This encryption level is displayed as a Cipher strength.
Summary of Contents for Modero NXD-500i
Page 4: ......
Page 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Page 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...