Configuring Communication
28
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
4.
Press the optional
Host Name
field to open a Keyboard and enter the Host Name information.
5.
Press
Done
after you are finished assigning the alpha-numeric string of the host name.
6.
Do not alter any of the remaining greyed-out fields in the IP Settings section.
Once the panel is rebooted, these
values are obtained by the unit and displayed in the DNS fields after power-up
.
7.
Press the
Back
button to return to the Protected Setup page.
8.
Press the on-screen
Reboot
button to save any changes and restart the panel.
IP Settings section - Configuring a Static IP Address over Ethernet
1.
Select
Protected Setup
>
System Settings
located on the lower left to open the
System Settings
page.
2.
Locate the
IP Settings
section of this page.
3.
Toggle the
DHCP/Static
field (
from the IP Settings section
) until the choice cycles to
Static
.
4.
Press the
IP Address
field to open a Keyboard and enter the Static IP Address provided by your System
Administrator.
5.
Press
Done
after you are finished entering the IP information.
6.
Repeat the same process for the
Subnet Mask
and
Gateway
fields.
7.
Press the optional
Host Name
field to open the Keyboard and enter the Host Name information.
8.
Press
Done
after assigning the alpha-numeric string of the host name.
9.
Press the
Primary DNS
field to open a Keyboard, enter the Primary DNS Address provided by your System
Administrator, and press
Done
when compete. Repeat this process for the
Secondary DNS
field.
10.
Press the
Domain
field to open a Keyboard, enter the resolvable domain Address provided by your System
Administrator, and press
Done
when complete.
11.
Navigate to the
Master Connection
section of this page to begin configuring the communication parameters for the
target Master.
Step 2: Choose a Master Connection Mode Setting
The Master Connection section of the System Connection page uses three Ethernet MODE settings.
URL
is the most common method.
Master Connection MODE
options:
DHCP will register the unique factory-assigned MAC Address on the panel, and once
the communication setup process is complete, reserve an IP Address, Subnet Mask,
and Gateway values from the DHCP Server.
This information can be found in either the: Workspace- System name > Define
Device section of the code that defines the properties for the panel, or in the Device
Addressing/Network Addresses in the
Tools > NetLinx Diagnostics
dialog.
Check with your System Administrator for a pre-reserved Static IP Address assigned
to the panel. This address must be obtained before Static assignment of the panel
continues.
•
URL
(
Uniform Resource Locator
) is the address that defines the route to a file on the Web or any other
Internet facility. In this system, the panel acts as a "Client" and the Master acts as a Server (in that Clients
attach to it).
•
LISTEN
sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP from its URL
list). In this system, the panel acts as a "Server" (in that Clients attach to it) and the Master acts as a
"Client".
Summary of Contents for Modero NXD-500i
Page 4: ......
Page 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Page 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...