Installation
13
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
3.
Remove the Faceplate/bezel (
A
in
FIG. 10) from the main NXD-500i unit (
B
in
FIG. 10) by gripping the faceplate
and pulling up and out with gentle force.
4.
Thread the incoming Ethernet and USB wiring from their terminal sources through the surface opening. Leave
enough slack in the wiring to accommodate any re-positioning of the panel.
5.
Connect all connectors to their corresponding locations along the left side of the un-powered NXD-500i panel.
The USB connectors can be from either a USB extension cable or a wireless USB RF transmitter.
6.
Test the incoming wiring by connecting the panel connections to their terminal locations. Verify that the panel is
receiving power and functioning properly before finalizing the installation.
7.
Carefully slide the main unit into the cutout, making sure that the locking tabs lie flush against the back box.
8.
Insert and secure three #4 Mounting Screws (not included) into the corresponding holes located along the sides of
the NXD-500i, using a grounded Phillips-head screwdriver, until the unit is secure and flush against the wall
(FIG. 10).
9.
Place the Faceplate/Trim Ring assembly (
A
in
FIG. 10) back onto the device (
B
in
FIG. 10).
Make sure to align the
Microphone, Light, and PIR Motion sensor locations to their respective openings on the front bezel/faceplate.
Installing an NXD-500i into a Rack Mount Kit (NXA-RK5)
The NXA-RK5 is a 19" (48.26 cm) wide metal rack-mount (with black matte finish) measuring 3 rack units high.
1.
Remove the Faceplate/Trim Ring assembly from the main NXD-500i unit.
2.
Thread the incoming Ethernet and USB wiring from their terminal sources through the surface opening, leaving
enough slack in the wiring to accommodate any re-positioning of the panel.
3.
Connect all data and power wiring connectors to their corresponding locations along the left side of the device.
The USB connectors can be from either a USB extension cable or a wireless USB RF transmitter.
FIG. 10
Wall Mount panel installation configuration for flat surfaces
B
- Main NXD-500i unit
Install the three #4 Mounting Screws
Flat installation surface
A
- Faceplate/Trim Ring
Locking Tab
Attachment is done
along the edges
of the cutout
(not included) into these three holes
(suggested length of screws is 0.25")
Do not disconnect the connectors from the touch panel. The unit must be installed
with the necessary connectors before being inserted into the solid surface.
Summary of Contents for Modero NXD-500i
Page 4: ......
Page 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Page 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...