Installation
14
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
4.
Test the incoming wiring by connecting the panel connections to their terminal locations. Verify that the panel is
receiving power from the PoE Injector and functioning properly.
5.
Carefully insert the device into the NXA-RK5.
6.
Secure the panel to the NXA-RK5 mount by first inserting and then tightening the three included #4-40 screws.
7.
Insert the NXA-RK5 (with the connected NXD-500i unit) into the equipment rack, making sure to align the screw
holes along the sides on the NXA-RK5 with the holes in the equipment rack.
8.
Use a grounded Phillips-head screwdriver to secure the NXA-RK5 to the equipment rack using the included #10-32
screws.
9.
Place the Faceplate/Trim Ring assembly back onto the main NXD-500i device. Make sure to align the Microphone,
Light, and PIR Motion sensor locations to their respective openings on the front faceplate/bezel.
10.
Reconnect the terminal Ethernet and USB wiring to their respective terminal locations on the Ethernet port or
NetLinx Master.
Wiring Guidelines for the NXD-500i Panel
The NXD-500i panel utilizes the Power over Ethernet protocol, where it draws power directly from its Ethernet
connection. Because of this, the panel has no need for standard power inputs or outputs.
Ethernet/RJ-45 Port: Connections and Wiring
FIG. 11 describes the blink activity for the Ethernet 10/100 Base-T RJ-45 connector and cable. The Ethernet cable is
connected to the side of the Wall Mount panels.
The following table lists the pinouts, signals, and pairing for the Ethernet connector.
FIG. 12 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector and cable.
Do not disconnect the connectors from the touch panel. The unit must be installed
with the necessary connectors before being inserted into the equipment rack.
FIG. 11
Ethernet connector (showing communication and connection LEDs)
Ethernet RJ-45 Pinouts and Signals
Pin
Signals
Connections
Pairing
Color
1
TX +
1 --------- 1
1 --------- 2
Orange-White
2
TX -
2 --------- 2
Orange
3
RX +
3 --------- 3
3 --------- 6
Green-White
4
PoE power
4 --------- 4
Blue
5
PoE power
5 --------- 5
4 --------- 5
Blue-White
6
RX -
6 --------- 6
Green
7
PoE power
7 --------- 7
7 --------- 8
Brown-White
8
PoE power
8 --------- 8
Brown
FIG. 12
RJ-45 wiring diagram
ETHERNET
10/100
A
L
A
- Activity LED (yellow)
lights when receiving or
transmitting Ethernet
data packets
L
- Link LED (green) lights when
the Ethernet cables are connected
and terminated correctly.
Summary of Contents for Modero NXD-500i
Page 4: ......
Page 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Page 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...