Programming
110
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
Intercom Commands (Cont.)
^ICM
Modifies an intercom call. The microphone and/or speaker are activated based on the initial
mode value of the intercom start command and the audio data packet flow is started upon
receipt of this command by the panel.
Note
: For backwards compatibility, both ^ICM-TALK and ^ICM-LISTEN are supported.
However, the TALK and LISTEN subcommands are ignored.
Syntax:
SEND_COMMAND <DEV>,"`^ICM-TALK`"
Variables:
None.
Example:
SEND_COMMAND TP1,"`^ICM-TALK`"
^ICS-
Intercom start. Starts a call to the specified IP address and ports, where initial mode is either 1
(talk) or 0 (listen) or 2 (both). If no mode is specified 0 (listen) is assumed.
Note
: No data packets will actually flow until the intercom modify command is sent to the
panel.
Syntax:
SEND_COMMAND <DEV>,"'^ICS-<IP>,<TX UDP port>,<RX UDP port>,<initial mode>'"
Variables:
IP = IP Address of panel to connect with on an Intercom call.
TX UDP port = UDP port to transmit to.
RX UDP port = UDP port to receive from.
initial mode = 0 (listen) or 1 (talk) or 2 (hands free). 0 is the default.
Examples:
Example of setting up a hands free unicast call between two panels:
SEND_COMMAND TP1, "^ICS-192.168.0.3,9000,9002,2"
SEND_COMMAND TP2, "^ICS-192.168.0.4,9002,9000,2"
Example of setting up a multicast call where the first panel is paging two other panels:
SEND_COMMAND TP1, "^ICS-239.252.1.1,9002,9000,1"
SEND_COMMAND TP2, "^ICS-239.252.1.1,9002,9000,0"
SEND_COMMAND TP3, "^ICS-239.252.1.1,9002,9000,0"
Example of setting up a baby monitor call where the first panel is listening to the microphone
audio coming from the second panel:
SEND_COMMAND TP1, "^ICS-192.168.0.3,9000,9002,0"
SEND_COMMAND TP2, "^ICS-192.168.0.4,9002,9000,1"
^ICE'
Intercom end - this command terminates an intercom call/connection.
Syntax:
SEND_COMMAND <DEV>,"'^ICE'"
Variables:
None.
Example:
SEND_COMMAND TP1,"'^ICE'"
SEND_COMMAND TP2,"'^ICE'"
Terminates an intercom call between two panels.
^ICM-TALK
See
^ICM
on page 110.
Syntax:
SEND_COMMAND <DEV>,"'^ICM-TALK'"
Variables:
None.
Example:
SEND_COMMAND TP1,"'^ICM-TALK'"
Summary of Contents for Modero NXD-500i
Page 4: ......
Page 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Page 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...