Upgrading Modero Firmware
38
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
3.
Click the
Communications Settings
button to open the
Communications Settings
dialog (FIG. 34).
4.
Click on the
NetLinx Master
radio button from the
Platform Selection
section to work as a NetLinx Master.
5.
Click on the
Virtual Master
radio box from the
Transport Connection Option
section to configure the PC to
communicate directly with a panel.
Everything else, such as the Authentication, is greyed-out because the communication is not going through the
Master’s UI.
6.
Click the
Edit Settings
button on the
Communications Settings
dialog to open the
Virtual NetLinx Master Settings
dialog (FIG. 33).
7.
Enter the System number (default is
1
).
8.
Click
OK
three times to close the open dialogs, save the settings, and return to the main NetLinx Studio application.
FIG. 33
Master Communication Settings dialog box
FIG. 34
Communication Settings dialog box
FIG. 35
Virtual NetLinx Master Settings dialog