Configuring Communication
30
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
3.
Select
Settings
>
Master Communication Settings
, from the Main menu to open the
Master Communication
Settings
dialog (FIG. 21).
4.
Click the
Communications Settings
button to open the
Communications Settings
dialog (FIG. 22).
5.
Click on the
NetLinx Master
radio button from the
Platform Selection
section to indicate that you are working as a
NetLinx Master.
6.
Click on the
Virtual Master
radio box from the
Transport Connection Option
section to indicate you are wanting
to configure the PC to communicate with a panel.
All other fields will be greyed out because the Master’s UI is not being used.
7.
Click the
Edit Settings
button on the
Communications Settings
dialog to open the
Virtual NetLinx Master Settings
dialog (FIG. 23).
8.
From within this dialog, enter the System number (
default is 1
) and note the IP Address of the target PC being used
as the Virtual Master.
This IP Address can also be obtained by following these procedures:
a.
On your PC, click
Start
>
Run
to open the
Run
dialog.
b.
Enter
cmd
into the Open field and click
OK
to open the command DOS prompt.
c.
From the
C:\>
command line, enter
ipconfig
to display the IP Address of the PC. This information is entered
into the
Master IP/URL
field on the panel.
9.
Click
OK
three times to close the open dialogs, save your settings, and return to the main NetLinx Studio
application.
10.
Click the
OnLine Tree
tab in the Workspace window to view the devices on the Virtual System.
The default System value is
one
.
11.
Right-click on the
Empty Device Tree/System
entry and select
Refresh System
to re-populate the list.
12.
Power-up your panel and press and hold the grey Front Setup Access button (
for 3 seconds
) to continue with the
setup process and proceed to the Setup page.
13.
Select
Protected Setup
>
System Settings
, located on the lower left, to open the
System Settings
page (FIG. 27).
The
System Number
is assigned to the Master within the NetLinx Studio application (these must match)
Enter the IP Address information of the PC used the Virtual Master in the
Master IP/URL
field.
When using a Virtual Master, there is no need to enter a User Name and Password.
14.
Press the
Master IP/URL
field to open a Keyboard and enter the IP Address of the PC used as the Virtual Master.
15.
Click
Done
to accept the new value and return to the
System Settings
page.
16.
Do not alter the Master Port Number value. This is the default value used by NetLinx.
17.
Press the
Back
button to return to the
Protected Setup
page.
FIG. 27
Sample System Connection page (for Virtual Master communication)
Summary of Contents for Modero NXD-500i
Page 4: ......
Page 12: ...viii NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom Table of Contents...
Page 32: ...Panel Calibration 20 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 130: ...Programming 118 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...
Page 134: ...Troubleshooting 122 NXD 500i 5 Modero Wall Flush Mount Touch Panel with Intercom...