background image

 

 

Page 1 of 9 

 

 

 
 

Agilent N5416A USB 2.0 Compliance Test Software 
Release Notes 

 
 
Agilent N5416A Software Version 03.81 
Released Date: 28 October 2013 
Minimum  Infiniium  Oscilloscope  Baseline  Version:  4.20  (90000  series), 
4.6(9000 series) 
Minimum Infiniium Oscilloscope Baseline Version: 4.60.0005 (90000 series), 
4.6(9000 series) 
 
File Name: SetupInfUSBXP0381.exe

 

 
Modifications: 
1. 

To upgrade framework to 0391 and support layer to 2.01 

2. 

Fixed the problem where Upstream Low Speed test able to run at first 

trial, however at second trial, the test aborts with error message "Did not find 
correct waveform

”. 

3. 

For Inrush Current set the sensitivity to HIGH and the Acquisition to High 

Resolution Auto mode.  
4. 

Fixed test abort intermittently when ran Suspend / Resume Timing, to 

turn off Bandwith limit to fix this issue. (This issue only affect window 7, it had 
been fixed by using baseline 4.6) 
5. 

Fixed test abort occasionally on Signal Quality Test with error message 

"HSSQDevice0.tsv" was not found, especially when ran repetitive. This is due to 
waveform file was not properly saved. 
6. 

Fixed connection error where connection break when ran with 81130A. 

This is due to GPIB command error. (*IDN?;*OPT?) 

 

 
Agilent N5416A Software Version 03.80 
Released Date: 14 June 2013 
Minimum Infiniium Oscilloscope Baseline Version: 4.20 (90000 series), 4.20 
(9000 series) 
File Name: SetupInfUSBXP0380.exe

 

 
Modifications: 

  Embedded Host Test update

 

  Remove the lost from Agilent fixture using InfiniiSim. 

 
Agilent N5416A Software Version 03.74 
Released Date: 27 May 2013 

Summary of Contents for N5416A

Page 1: ...n to High Resolution Auto mode 4 Fixed test abort intermittently when ran Suspend Resume Timing to turn off Bandwith limit to fix this issue This issue only affect window 7 it had been fixed by using baseline 4 6 5 Fixed test abort occasionally on Signal Quality Test with error message HSSQDevice0 tsv was not found especially when ran repetitive This is due to waveform file was not properly saved ...

Page 2: ...3 72 Released Date 25 Sept 2011 Minimum Infiniium Oscilloscope Baseline Version 5 71 80000 series 2 40 90000 series 2 40 9000 series File Name SetupInfUSBXP0372 exe Modifications Upgraded framework to version 3 61 to support Windows 7 platform Replaced USB IF MATLAB scripts with USB IF s USBET dll Version of the USBET dll for this release is 1 12 Agilent N5416A Software Version 03 71 Released Date...

Page 3: ...urrent probe impedance detection bug Agilent N5416A Software Version 03 51 Released Date 25 September 2009 Minimum Infiniium Oscilloscope Baseline Version 5 71 80000 series 1 41 90000 series 2 00 9000 series File Name SetupInfUSBXP0351 exe Modifications Fixed algorithm for EL_38 and EL_40 Agilent N5416A Software Version 03 50 Released Date 22 June 2009 Minimum Infiniium Oscilloscope Baseline Versi...

Page 4: ...eleased Date 20 May 2008 Minimum Infiniium Oscilloscope Baseline Version 5 20 80000 series 1 00 90000 series File Name SetupInfUSBXP0340 exe Additions Supports the Hi Speed new fixture E2649 66401 E2649 66402 E2649 66403 and E2649 66404 Supports the Droop Drop tests new fixture in automatic and manual measurement method Supports the SMA connection measurement for the Hi Speed Signal Quality tests ...

Page 5: ...ion 5 20 80000 series 1 00 90000 series File Name SetupInfUSBXP0330 exe Additions Supports the Remote Interface Control Supports the Infiniium 90000 Series High Performance Oscilloscope Modifications Connection diagram for the Host Controller Packet Parameter is updated Non Monotonic hysteresis is set to 30mV by default ...

Page 6: ...SBXP0320 exe Additions Added manual method in Signal Eye Quality tests for Hi speed Full speed and low speed tests Added sensitivity option for the EL_28 Measure Device Chirp K Latency Test Modifications Images for the result are shown up to the worst 25 trials Supports Matlab script 2 30 provided by USB IF Used new specification for Rise Fall time tests ...

Page 7: ...le Name SetupInfUSBXP0310 exe Additions Supports Multitrial testing Added compliance features to allow customers to choose the hysteresis measurement level for non Monotonic Edge Test Added Noise reduction option checking system Modifications Trigger level is modified to 100mV for signal quality tests Only supports Matlab script 2 12 ...

Page 8: ...lloscope Baseline Version 05 20 00 File Name SetupInfUSBXP0302 exe Modifications Matlab migration from version 7 1 to version 7 5 Code change for triggering the last packet of signal in Host Hub Disconnect test Unit of measurement displayed at result has been corrected in Host Packet Parameter test ...

Page 9: ...mode Supports MATLAB script both versions 2 10 and 2 12 Data export tools to export test results into customer s database Debug features to allow customers to adjust trigger level and threshold level for Packet Parameters test and to allow customers to adjust total time range and trigger level for Inrush Current test Modifications Segregated test groups Device Hub Host OTG Changed algorithm for Re...

Reviews: