SEND_COMMANDs
31
Mio Modero R-4 Remote - Instruction Manual
Page Commands (Cont.)
@PPK
Kill a specific popup page from all pages. Kills refers to the deactivating (Off) of a popup window from all pages. If the pop-up
page is part of a group, the whole group is deactivated. This command works in the same way as the 'Clear Group' command in
TPDesign4.
Syntax:
SEND_COMMAND <DEV>,"'@PPK-<popup page name>'"
Variable:
• popup page name = 1 - 50 ASCII characters. Name of the popup page.
Example:
SEND_COMMAND Device,"'@PPK-Popup1'"
Kills the popup page 'Popup1' on all pages.
@PPM
Set the modality for a specific popup page to either Modal or Non-Modal. A Modal popup page, when active, only allows you to
use the buttons and features on that popup page. All other buttons on the panel page are inactivated.
Syntax:
SEND_COMMAND <DEV>,"'@PPM-<popup page name>;<mode>'"
Variables:
• popup page name = 1 - 50 ASCII characters. Name of the popup page.
• mode = NONMODAL converts a previously Modal popup page to a NonModal.
MODAL converts a previously NonModal popup page to Modal.
modal = 1 and non-modal = 0
Examples:
SEND_COMMAND Device,"'@PPM-Popup1;Modal'"
Sets the popup page 'Popup1' to Modal.
SEND_COMMAND Device,"'@PPM-Popup1;1'"
Sets the popup page 'Popup1' to Modal.
@PPN
Activate a specific popup page to launch on either a specified page or the current page. If the page name is empty, the current
page is used (see example 2). If the popup page is already on, do not re-draw it. This command works in the same way as the
'Show Popup' command in TPDesign4.
Syntax:
SEND_COMMAND <DEV>,"'@PPN-<popup page name>;<page name>'"
Variables:
• popup page name = 1 - 50 ASCII characters. Name of the popup page.
• page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On
Example:
SEND_COMMAND Device,"'@PPN-Popup1;Main'"
Activates 'Popup1' on the 'Main' page.
Example 2:
SEND_COMMAND Device,"'@PPN-Popup1'"
Activates the popup page 'Popup1' on the current page.
@PPT
Set a specific popup page to timeout within a specified time. Timeout is in 1/10 seconds. If timeout is empty, popup page will
clear the timeout.
Syntax:
SEND_COMMAND <DEV>,"'@PPT-<popup page name>;<timeout>'"
Variables:
• popup page name = 1 - 50 ASCII characters. Name of the popup page.
• timeout = timeout duration in 1/10ths of a second.
Example:
SEND_COMMAND Device,"'@PPT-Popup1;30'"
Sets the popup page 'Popup1' to timeout within 3 seconds.
@PPX
Close all popups on all pages. This command works in the same way as the 'Clear All' command in TPDesign4.
Syntax:
SEND_COMMAND <DEV>,"'@PPX'"
Example:
SEND_COMMAND Panel,"'@PPX'"
Close all popups on all pages.
@PSE
Set the show effect for the specified popup page to the named show effect.
Syntax:
SEND_COMMAND <DEV>,"'@PSE-<popup page name>;<show effect name>'"
Variables:
• popup page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.
• show effect name = Refers to the popup effect name being used.
Example:
SEND_COMMAND Device,"'@PSE-Popup1;Slide from Left'"
Sets the Popup1 show effect name to 'Slide from Left'.